16.5.3Connecting to the MELSERVO-J4,J3 Series

POINT

MELSERVO-J4, J3 Series

For details of the MELSERVO-J4, J3 Series, refer to the following manual.

See the technical manual for the MELSERVO- J4, J3 Series servo amplifiers.

Parameters of MELSERVO-J4, J3 Series

Enter the parameters of the MELSERVO-J4, J3 Series.

Item

 

Set value

Basic parameter

 

Station number setting: 0 to 31

No. PC20

 

(Default: 0)*1

 

Serial communication function selection

 

(Default: 0000)

 

Basic parameter No. PC21

 

 

(2) (1)

 

(1) Serial communication baud rate selection*2

 

0: 9600bps

Basic parameter

1: 19200bps

No. PC21

2: 38400bps

 

3: 57600bps

 

4: 115200bps

 

(2) Communication response delay time

 

selection

 

0:

Invalid

 

1:

Valid (Response after 800 s or longer

 

 

delay)

 

 

 

*1 Avoid duplication of the station No. with any of the other axes.

*2 Specify the same transmission speed as that of the GOT. For the transmission speed setting on the GOT side, refer to the following.

16.4.1 Setting communication interface (Communication settings)

POINT

(1)Parameter setting

Set the parameter at the pushbutton switch provided on the operation section of the servo amplifier or setup software.

Pushbutton switch provided on the operation section of the servo amplifier

MODE UP DOWN SET

(2)When changing the parameter

Turn off then on the servo amplifier to be effective the new parameter.

16.5.4Station number setting

Set each station number so that no station number overlaps.

The station number can be set without regard to the cable connection order. There is no problem even if station numbers are not consecutive.

Station

Station

Station

Station

Station

NO.3

NO.0

NO.1

NO.21

NO. 6

GOT

Examples of station number setting

(1)Direct specification

When setting the device, specify the station number of the servo amplifier of which data is to be changed.

Specification

range

0 to 31

(2)Indirect specification

When setting the device, indirectly specify the station number of the inverter of which data is to be changed using the 16-bit GOT internal data register (GD10 to GD25).

When specifying the station No. from 100 to 115 on GT Designer3,the value of GD10 to GD25 compatible to the station No.specification will be the station No.of the servo amplifier.

Specification

Compatible

Setting range

station NO.

device

 

100

GD10

 

 

 

 

101

GD11

 

 

 

 

102

GD12

 

 

 

 

103

GD13

 

 

 

 

104

GD14

 

 

 

 

105

GD15

 

 

 

 

106

GD16

 

 

 

0 to 31

107

GD17

For the setting other than the above, a

 

 

108

GD18

communication timeout error will occur.

 

 

109

GD19

 

 

 

 

110

GD20

 

 

 

 

111

GD21

 

 

 

 

112

GD22

 

 

 

 

113

GD23

 

 

 

 

114

GD24

 

 

 

 

115

GD25

 

 

 

 

(3)All station specification

Target station differs depending on write-in operation or read-out operation.

For write-in operation, all station will be a target.

For read-out operation, only one station will be a target.

16 - 16

16. SERVO AMPLIFIER CONNECTION

 

16.5 Setting on Servo Amplifier Side