10.4 PLC Side Setting
Model name |
| Reference | |
|
| QJ71LP21, |
|
MELSECNET/H network module |
| ||
| |||
|
|
| |
|
| QJ71BR11 |
|
|
|
|
|
|
| AJ71QLP21, |
|
MELSECNET/10 network |
| AJ71QLP21S, |
|
| AJ71QBR11, |
| |
module |
| ||
| A1SJ71QLP21, | ||
(QnA Series) |
|
| |
| A1SJ71QLP21S, |
| |
|
|
| |
|
| A1SJ71QBR11 |
|
|
|
|
|
MELSECNET/10 network |
| AJ71LP21, |
|
| AJ71BR11, |
| |
module |
| ||
| A1SJ71LP21, | ||
(A Series) |
|
| |
| A1SJ71BR1 |
| |
|
|
| |
|
|
|
|
This section describes the settings of the GOT and MELSECNET/H network module in the following case of system configuration.
When connecting the MELSECNET/H network module to the MELSECNET/10 network system, specify the MELSECNET/10 Mode as a network type.
POINT
MELSECNET/H network module
For details of the MELSECNET/H network module, refer to the following manual.
Q corresponding MELSECNET/H Network System Reference Manual (PLC to PLC network)
System configuration
■ [Controller Setting] of GT Designer3
■ Setting of the MELSECNET/10 communication unit
<GOT> (Use the default value for settings other than the following.)
Station No. | : 2 |
Mode | : Online |
Network No. | : 1 |
Network range assignment: LB0100H to LB01FFH | |
| LW0100H to LW01FFH |
MELSECNET/10 (PLC to PLC network)
<MELSECNET/H network module> *1
(Use the default value for settings other than the following.)
Station No. | : 1 |
Mode | : Online (10Mbps) |
Network type | : MNET/10 mode (Control station) |
Network No. | : 1 |
Total stations | : 2 |
Network range assignment: LB0000H to LB00FFH
LW0000H to LW00FFH
*1 The MELSECNET/H network module is mounted at slot 0 of the base unit.
The start I/O No. of the MELSECNET/H network module is set at "0".
POINT
When connecting to Q170MCPU
When connected to Q170MCPU, the start I/O No. of the MELSECNET/H network module is set to "70".
Switch setting of MELSECNET/H network module
Set the station number setting switch and mode setting switch.
QJ71LP21, |
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
| RUN | MNG |
|
| ||||||||||
RUN | MNG |
|
|
|
|
|
| |||||||||||
T.PASS | D.LINK |
| EXT.PW | T.PASS | D.LINK |
| ||||||||||||
SD | RD |
|
|
|
|
|
| SD | RD |
|
|
|
|
| ||||
ERR. | L ERR. |
|
| ERR. | L ERR. |
| ||||||||||||
STATION NO. | 1 | 2 | 3 | 4 |
|
| STATION NO. | 1 | 2 | 3 | 4 |
| ||||||
|
|
|
|
| 5 |
|
|
|
|
|
|
| 5 |
| ||||
X10 | 0 |
|
|
|
|
|
| X10 | 0 |
|
|
|
|
| ||||
9 |
| 7 |
| 6 |
|
|
| 9 | 8 | 7 | 6 |
|
| |||||
|
| 8 |
|
|
| (1) |
|
|
|
|
| (1) | ||||||
| 1 | 2 | 34 |
|
| 1 | 2 | 34 | ||||||||||
X1 | 0 |
|
|
|
| 5 |
|
| X1 | 0 |
|
|
|
| 5 |
| ||
9 |
| 7 |
| 6 |
|
|
| 9 | 8 | 7 | 6 |
|
| |||||
|
| 8 |
|
|
|
|
|
|
|
|
|
| ||||||
IN |
|
|
|
|
|
|
|
|
| IN |
|
|
|
|
|
|
|
|
|
| 34 | 5 |
|
|
| (2) |
|
| 2 | 3 | 456 |
| (2) | ||||
| 2 |
|
|
| 67 | EXT..PW |
|
|
|
|
| 7 | ||||||
MODE | 01 |
|
|
|
| 8 | MODE | 01 |
|
|
|
| 8 | |||||
E |
|
|
| A | 9 |
| E |
|
|
| A | 9 | ||||||
F | DCB |
|
|
|
| F | DCB |
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
| +24V |
|
|
|
|
|
|
|
|
|
OUT |
|
|
|
|
|
|
|
| 24G | OUT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| (FG)24G |
|
|
|
|
|
|
|
|
|
QJ71LP21 |
|
|
|
|
|
|
|
| QJ71LP21 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
QJ71BR11 |
|
|
|
|
|
|
|
|
|
|
| |||||||
QJ71BR11 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
RUN | MNG |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
T.PASS | D.LINK |
|
|
|
|
|
|
|
|
|
|
| ||||||
SD | RD |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
ERR. | L ERR. |
|
|
|
|
|
|
|
|
|
|
| ||||||
STATION NO. |
| 2 | 34 |
|
|
|
|
|
|
|
|
|
|
| ||||
X10 | 1 |
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
| 5 |
|
|
|
|
|
|
|
|
|
|
| |||
0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| 9 | 8 | 7 |
| 6 |
| (1) |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
X1 | 1 | 2 | 34 |
|
|
|
|
|
|
|
|
|
| |||||
0 |
|
|
|
| 5 |
|
|
|
|
|
|
|
|
|
|
| ||
| 9 | 8 | 7 |
| 6 |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| 2 | 3 | 4 | 56 |
| (2) |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| 7 |
|
|
|
|
|
|
|
|
|
| ||||
MODE | 01 |
|
|
|
| 8 |
|
|
|
|
|
|
|
|
|
| ||
E |
|
| A9 |
|
|
|
|
|
|
|
|
|
| |||||
F | DCB |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
QJ71BR11
10 - 12 | 10. MELSECNET/10 CONNECTION (PLC TO PLC NETWORK) |
| 10.4 PLC Side Setting |