13.4 PLC Side Setting
The GOT operates as the stations of which are shown below in the
Station data | Description | |
Station type | Intelligent device station, Ver.1 intelligent device | |
station or Ver.2 intelligent device station | ||
| ||
|
| |
Number of stations | Station 1 or Station 4 | |
occupied | ||
| ||
|
|
The switch settings and parameter settings of the PLC side
| Model name |
| Refer to | |
| Connecting |
|
|
|
| with |
| QJ61BT11, | |
| Ver.1 |
| QJ61BT11N | |
|
|
| ||
| compatible |
|
|
|
|
|
|
|
|
Connecting |
|
|
| |
with Ver.2 |
| QJ61BT11N | ||
module |
| |||
compatible |
|
|
| |
(Q Series) |
|
|
| |
|
|
|
| |
| Connecting |
|
|
|
| with Ver.1/ |
|
|
|
| Ver.2 |
| QJ61BT11N | |
| compatibles |
|
|
|
| mixed |
|
|
|
|
|
|
|
|
|
| AJ61QBT11, | ||
(QnA Series) |
|
| A1SJ61QBT11 | |
|
|
| ||
|
|
|
|
|
|
| AJ61BT11, | ||
(A Series) |
|
| A1SJ61BT11 | |
|
|
| ||
|
|
|
|
|
HINT
Number of stations occupied
The number of stations occupied is setting for determining number of link device points (RX/RY/ RWw/RWr) used by the GOT.
To use multiple numbers of link device points in the case of cyclic transmission between the GOT and CC- Link module, set the number of stations occupied as the exclusive station 4.
The number of link device points at the exclusive station 1 and 4 is shown below.
|
|
| Expanded cyclic setting |
|
| ||||
| Single | Double | Quadruple | Octuple | |||||
Link | Exclu | Exclu | Exclu | Exclu | Exclu | Exclu | Exclu | Exclu | |
device | |||||||||
sive | sive | sive | sive | sive | sive | sive | sive | ||
| |||||||||
| statio | statio | statio | statio | statio | statio | statio | statio | |
| n 1 | n 4 | n 1 | n 4 | n 1 | n 4 | n 1 | n 4 | |
Remote | 32 | 128 | 32 | 224 | 64 | 448 | 128 | 896 | |
input (RX) | points | points | points | points | points | points | points | points | |
|
|
|
|
|
|
|
|
| |
Remote | 32 | 128 | 32 | 224 | 64 | 448 | 128 | 896 | |
output (RY) | points | points | points | points | points | points | points | points | |
|
|
|
|
|
|
|
|
| |
Remote | 4 | 16 | 8 | 32 | 16 | 64 | 32 | 128 | |
register | |||||||||
points | points | points | points | points | points | points | points | ||
(RWw) | |||||||||
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |
Remote | 4 | 16 | 8 | 32 | 16 | 64 | 32 | 128 | |
register | |||||||||
points | points | points | points | points | points | points | points | ||
(RWr) | |||||||||
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
Link device | Number of stations occupied | ||
Exclusive station | Exclusive station 4 | ||
| |||
Remote input (RX) | 32 points | 128 points | |
|
|
| |
Remote output (RY) | 32 points | 128 points | |
|
|
| |
Remote register (RWw) | 4 points | 16 points | |
|
|
| |
Remote register (RWr) | 4 points | 16 points | |
|
|
| |
|
|
|
13 - 12 | 13. |