(2) When connecting to the CH2 side
|
|
| Bit |
|
|
|
|
|
|
Switch | Positi | Specifi |
| Description | Set | ||||
No. |
| value*3 | |||||||
ed |
| ||||||||
|
|
|
|
| |||||
| on | value |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
| b0 | OFF |
| Operation |
|
| |||
|
| setting |
|
| |||||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| ||
| b1 | OFF |
| Data bit |
|
| |||
|
|
|
|
|
|
|
|
| |
| b2 | OFF |
| Parity |
|
| |||
|
| bit |
|
|
| ||||
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |
| b3 | OFF |
| Even/odd |
|
| |||
|
| parity |
|
| |||||
|
|
|
| CH2 |
|
| |||
|
|
|
|
|
|
| (Operates |
| |
| b4 | OFF | Stop bit |
| |||||
| transmiss |
| |||||||
| according |
| |||||||
|
|
|
| ion | Sum |
|
| ||
|
|
|
|
| to the GOT |
| |||
Switch 3 |
|
|
| settings*1 |
| 0000H | |||
b5 | OFF | check | side | ||||||
|
|
|
|
| code |
| specificatio |
| |
|
|
|
|
|
|
|
| ns.) |
|
|
|
|
|
| Write |
|
| ||
|
|
|
|
|
|
|
| ||
| b6 | OFF |
| during |
|
| |||
|
|
|
|
| RUN |
|
|
| |
|
|
|
|
|
|
|
|
| |
|
|
|
|
| Setting |
|
| ||
| b7 | OFF |
| modifica- |
|
| |||
|
|
|
|
| tions |
|
|
| |
|
|
|
|
|
|
|
| ||
| b8 to | ― | CH2 transmission |
|
| ||||
| b15 | speed setting*2 |
|
|
| ||||
|
|
|
|
| |||||
|
|
|
| CH2 Communication | GX |
| |||
Switch 4 |
|
| ― | Developer | 0000H | ||||
|
| protocol setting |
| ||||||
|
|
|
|
| connection |
| |||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| ||
Switch 5 |
|
| ― | Station number setting | 0th station | 0000H | |||
|
|
|
|
|
|
|
|
| |
*1 |
| The module operates under the following transmission | |||||||
|
| specifications. |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| Transmission specifications |
|
| Setting details | ||||
|
| Operation setting |
|
| Independent |
| |||
|
|
|
|
|
|
|
|
| |
|
| Data bit |
|
|
| 8bits |
|
| |
|
|
|
|
|
|
|
|
| |
|
| Parity bit |
|
|
| Yes |
|
| |
|
|
|
|
|
|
|
| ||
|
| Even/odd parity |
|
| Odd |
|
| ||
|
|
|
|
|
|
|
|
| |
|
| Stop bit |
|
|
| 1bit |
|
| |
|
|
|
|
|
|
|
| ||
|
| Sum check code |
|
| Yes |
|
| ||
|
|
|
|
|
|
|
|
|
|
*2 The serial communication module operates at the transmission speed set on the GOT.
*3 When the value of switch setting is other than "0", the setting of [Format] and [Transmission Speed] on the GOT side are required to be changed.
POINT
(1)When the [intelligent function module switch setting] has been set
After writing PLC parameters to the PLC CPU, turn the PLC CPU OFF then back ON again, or reset the PLC CPU.
(2)Connection of multiple GOTs
To some serial communication module models, two GOTs can be connected using both CH1 and CH2.
Model |
| Connection of 2 GOTs | ||
Function version A | Function version B | |||
| ||||
|
|
| ||
|
|
|
| |
| - |
| ||
|
|
|
| |
|
| - | ||
|
|
|
| |
: 2 GOTs connectable, | : 1 GOT connectable, |
(3)When connecting to the modem interface module When the modem interface module is connected, only CH2 can be used.