Ethernet parameter settings of FX3U-ENET-

ADP

(1)Ethernet settings

Set the Ethernet parameter at [FX Parameter] on GX Works2.

To set FX3U-ENET-ADP, GX Works2 Ver.1.90U or later is required.

For details on the setting of FX3U-ENET-ADP, refer to the following manual.

FX3U-ENET-ADP User's Manual

Item

Setting

Setting

(with GOT connected)

 

 

Channel

CH1 or CH2*1

 

IP Address

192.168.1.250*2

 

Open Settings

Refer to (2).

 

 

 

 

Communication Data

 

 

Code

 

 

 

 

 

Disable direct

 

 

connection to

(Use default value.)

 

MELSOFT

 

 

 

Do not respond to search for CPU on network

:Required :Set if necessary :Not required

*1 Set a channel according to the installation position of FX3U- ENET-ADP on the CPU body.

*2 The default value of IP address is 192.168.1.250. Set the IP address corresponding to the system configuration.

POINT

When changing Ethernet parameter

After writing Ethernet parameters to the PLC CPU, turn the PLC CPU OFF then back ON again.

(2) Open settings

Item

Setting

Setting

(with GOT connected)

 

 

Protocol

TCP

 

 

 

 

Open System

MELSOFT connection

 

 

 

 

POINT

When connecting to multiple GOTs and peripheral devices

The number of protocols equivalent to that of the GOTs and devices must be set.

\

8 - 40

8. ETHERNET CONNECTION

 

8.4 PLC Side Setting