Ethernet parameter settings of
ADP
(1)Ethernet settings
Set the Ethernet parameter at [FX Parameter] on GX Works2.
To set
For details on the setting of
Item | Setting | Setting | |
(with GOT connected) | |||
|
| ||
Channel | CH1 or CH2*1 |
| |
IP Address | 192.168.1.250*2 |
| |
Open Settings | Refer to (2). |
| |
|
|
| |
Communication Data |
|
| |
Code |
|
| |
|
|
| |
Disable direct |
|
| |
connection to | (Use default value.) |
| |
MELSOFT |
| ||
|
|
Do not respond to search for CPU on network
:Required :Set if necessary :Not required
*1 Set a channel according to the installation position of FX3U-
*2 The default value of IP address is 192.168.1.250. Set the IP address corresponding to the system configuration.
POINT
When changing Ethernet parameter
After writing Ethernet parameters to the PLC CPU, turn the PLC CPU OFF then back ON again.
(2) Open settings
Item | Setting | Setting | |
(with GOT connected) | |||
|
| ||
Protocol | TCP |
| |
|
|
| |
Open System | MELSOFT connection |
| |
|
|
|
POINT
When connecting to multiple GOTs and peripheral devices
The number of protocols equivalent to that of the GOTs and devices must be set.
\
8 - 40 | 8. ETHERNET CONNECTION |