When connecting the GOT and PC with Ethernet

(1)When connecting the GOT and PLC in Bus connection

The following shows the software and the accessible PLC CPUs.

PLC CPU

Software

QCPU (Q mode), C Controller module

GX Works2 *1, MX Component *2, MX Sheet*3, Setting/Monitoring tool for C Controller

module*8

 

Motion controller CPU (Q series)

MT Works2*4

MELSERVO(MR-J3-B) *5

MR Configurator2*6

MELSERVO(MR-J4-B) *5

MR Configurator2*7

*1 GX Works2 Version 1.48A or later is required to use the FA transparent function.

*2 MX Component Version 3.15R or later is required to use the FA transparent function.

*3 MX Component Version 3.15R or later is required for MX Sheet to use the FA transparent function.

*4 Use MT Works2 Version 1.25B or later for MT Works2.

*5 A motion controller is required between the GOT and PLC in bus connection.

*6 Use MR Configurator2 Version 1.07H or later for MR Configurator2.

*7 Use MR Configurator2 Version 1.09K or later for MR Configurator2.

*8 Setting/Monitoring tool for C Controller module Version 4.00A or later is required to use the FA transparent function.

(2)When connecting the GOT and PLC in direct CPU connection The following shows the software and the accessible PLC CPUs.

PLC CPU

Software

QCPU (Q mode)

GX Works2 *1, MX Component *3, MX Sheet*4

LCPU*2

GX Works2 *1, MX Component *3, MX Sheet*4

FXCPU

GX Works2*5

Motion controller CPU (Q series)

MT Works2*6

MELSERVO(MR-J3-B)*9

MR Configurator2*7

MELSERVO(MR-J4-B)*9

MR Configurator2*8

*1 GX Works2 Version 1.48A or later is required to use the FA transparent function.

*2 The adapter (L6ADP-R2) is required.

*3 MX Component Version 3.15R or later is required to use the FA transparent function.

*4 MX Component Version 3.15R or later is required for MX Sheet to use the FA transparent function.

*5 GX Works2 Version 1.73B or later is required for GX Works2 to use the FA transparent function.

*6 MT Works2 Version 1.25B or later is required for MT Works2 to use the FA transparent function.

*7 MR Configurator2 Version 1.07H or later is required for MR Configurator2 to use the FA transparent function. *8 MR Configurator2 Version 1.09K or later is required to use the FA transparent function.

*9 A motion controller is required between the GOT and PLC in direct CPU connection.

(3)When connecting the GOT and PLC in computer link connection The following shows the software and the accessible PLC CPUs.

PLC CPU

Software

QCPU (Q mode)

GX Works2 *1, MX Component *2, MX Sheet*3

LCPU*2

GX Works2 *1, MX Component *2, MX Sheet*3

*1 GX Works2 Version 1.48A or later is required to use the FA transparent function.

*2 MX Component Version 3.15R or later is required to use the FA transparent function.

*3 MX Component Version 3.15R or later is required for MX Sheet to use the FA transparent function.

Connecting the GOT and personal computer with Modem

(1)When connecting the GOT and PLC in bus connection

The following shows the software and the accessible PLC CPUs.

 

PLC CPU

Software

QCPU (Q mode)

 

GX Developer*1

 

GX Works2 *2

 

 

*1

GX Developer Version 8.78G or later is required to use the FA transparent function.

*2

GX Works2 Version 1.16S or later is required to use the FA transparent function.

(2)When connecting the GOT and PLC in direct CPU connection The following shows the software and the accessible PLC CPUs.

PLC CPU

Software

QCPU (Q mode)

GX Developer*1

GX Works2 *2

 

FXCPU

GX Developer*1

*1 GX Developer Version 8.78G or later is required to use the FA transparent function. *2 GX Works2 Version 1.16S or later is required to use the FA transparent function.

17

ROBOT CONTROLLER CONNECTION

18

CNC CONNECTION

19

CONNECTION

GOT MULTI-DROP

20

MULTIPLE-GT14, GT12, GT11, GT10 CONNECTION FUNCTION

21

FUNCTION

MULTI-CHANNEL

22

FUNCTION

FA TRANSPARENT

22. FA TRANSPARENT FUNCTION

22 - 9

22.2 Compatible Software