2.6 MELSEC-FX
1
The device ranges that can be set when selecting
| Device name | Setting range | Device No. | |||
| representation | |||||
|
|
|
|
| ||
| Input relay (X) | X0 | to | X377 | Octal | |
|
|
|
|
| ||
| Output relay (Y) | Y0 | to | Y377 | ||
|
| |||||
|
|
|
|
|
| |
| Auxiliary relay (M) | M0 | to | M7679 |
| |
|
|
|
|
|
| |
device | Special auxiliary relay (M) | M8000 | to | M8511 |
| |
|
|
|
| Decimal | ||
State (S) | S0 | to | S4095 | |||
|
|
|
|
| ||
Timer contact (T) | T0 | to | T511 |
| ||
Bit |
|
|
|
|
| |
Counter contact (C) | C0 | to | C255 |
| ||
|
|
|
| |||
|
| Specified bit of the |
| |||
| Word device bit*1 | following word devices | ― | |||
| (Except Timer (set value) | |||||
|
|
| ||||
|
| and Counter (set value)) |
| |||
|
|
|
|
|
| |
| Data register (D) | D0 | to | D0999 |
| |
| File register (D) | D1000 | to | D7999 |
| |
|
|
|
|
|
| |
| Special data register (D) | D8000 | to | D8511 |
| |
|
|
|
|
|
| |
| Timer (current value) (T) | T0 | to | T511 |
| |
|
|
|
|
|
| |
| Counter (current value) | C0 | to | C255 |
| |
| (C) |
| ||||
|
|
|
|
| ||
|
|
|
|
|
| |
device | Timer (set value) (TS)*3*5 | TS0 | to | TS511 |
| |
Counter (set value) | CS0 | to | CS255 |
| ||
(CS)*4*5 | Decimal | |||||
|
|
| ||||
Word |
|
|
|
|
| |
Extension register (R) | R0 | to | R32767 |
| ||
|
|
|
|
| ||
| Index register (V) | V0 | to | V7 |
| |
|
|
|
|
|
| |
| Index register (Z) | Z0 | to | Z7 |
| |
|
|
|
|
|
| |
| Buffer memory (BM)*7 | BM0 | to | BM32767 |
| |
|
| Converting the above bit |
| |||
| Bit device word*2*6 | devices into words |
| |||
| (Except Timer contact |
| ||||
|
|
| ||||
|
| and Counter contact) |
| |||
|
|
|
|
|
|
*1 When executing the touch switch function set during the bit specification of the word device, do not write any data to the word device through the sequence program.
*2 The device No. must be set in multiples of 16.
*3 Only
*4 For CS0 to CS199, only
For CS200 to CS255, only
*5 Monitoring or writing is not possible in the continuous device designation mode.
In addition, setting values of the timer and counter, which are not used for the program, cannot be monitored. If monitoring is executed, a reading error occurs.
*6 This is not supported by GT10.
*7 Can be used only for special blocks or special units compatible with FX1N, FX1NC, FX2N, FX2NC, FX3G, FX3GC, FX3U, FX3UC.
(Except
POINT
If using the 16 bit specification for a buffer memory of 32 bit data, monitoring and writing may not be executed normally.
For the data size of each buffer memory, refer to the following.
User's Manual of the special block or special module
•When reading from/writing to the special block or special module by interrupt processing of the sequence program, monitoring/writing from GOT to the buffer memory may not be executed normally.
(2)How to select a keyword protection level
For equipment that are allowed to operate the FX PLC online, 3 levels of protection level can be set. When monitoring or changing settings by any online equipment is required, set a keyword referring to the following.
(a)When setting the keyword only
Select a protection level by the initial letter of the keyword.
All operation protect: Set a keyword with the initial letter "A", "D" to "F", or "0" to "9". Incorrect write/read protect: Set a keyword with the initial letter "B".
Incorrect write protect: Set a keyword with the initial letter "C".
(b)When setting the keyword and 2nd keyword Select a protection level by [Registration condition].
(3)Monitoring availability at each keyword protection level
The following shows the device monitoring availability at each keyword protection level.
|
| When registering the | When registering the | Keyword | ||||
|
| keyword and 2nd | ||||||
|
| keyword only | not | |||||
|
| keyword |
| |||||
|
|
|
|
|
| registered | ||
Item |
| Incorrect |
|
|
|
| ||
All | Incorrect | All online | Read/ | Write | or | |||
|
| operation | write/ | write | operation | write | protection | |
|
| read | protect | |||||
|
| protect | protect | protect | protect | cancelled | ||
|
|
| protect |
|
|
|
|
|
Monitoring |
|
|
|
|
|
|
| |
devices |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| T, C set |
|
|
|
|
|
|
|
| value |
|
|
|
|
|
|
|
| and file | *1 | *1 | *1 |
|
|
|
|
| register |
|
|
|
| |||
Changing | (D1000 |
|
|
|
|
|
|
|
devices | and the |
|
|
|
|
|
|
|
| following) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Other |
|
|
|
|
|
|
|
| than |
|
|
|
|
|
|
|
| above |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*1 When the T, C set values are specified indirectly, changing devices is available.
PREPARATORYFORPROCEDURESMONITORING 2
RANGESETBE
DEVICE CANTHAT 3
RANGEACCESS MONITORINGFOR 4
MONITORTOREDUNTANTSYSTEM HOW 5
CONNECTIONBUS 6
DIRECTTOCONNECTIONCPU 7
LINK
(1)Precautions when using the buffer memory
•When the power supply of the special block or special module is turned off, the contents of the buffer memory are initialized, except for some keeping areas.
•When the buffer memory is monitored by the GOT, the PLC scan time may increase instantly.
•Use the 16 bit specification for the buffer memory of 16 bit data. Use the 32 bit specification for the buffer memory of 32 bit data.
(4)Difference between all online operations prohibition and all operations prohibition
When specifying all online operations prohibition, displaying devices and inputting data with programming tools or GOT are all prohibited. When all operations are prohibited, displaying devices and inputting data with the GOT are enabled while all operations using programming tools are prohibited.
COMPUTER CONNECTION 8
ETHERNETCONNECTION
2. DEVICE RANGE THAT CAN BE SET | 2 - 13 |