Parameter settings (Connection to Universal model QCPU) of System configuration2 (Network Type: Extended mode)
(1)[Network parameter] of GX Works2
(a)Network parameter
|
|
| Setting necessity |
Item |
| Set value | at GOT |
|
|
| connection |
Network Type |
| CC IE Control Ext. Mode |
|
| (Control station) (fixed) |
| |
|
|
| |
|
|
|
|
Start I/O No.*1 |
| 0000H |
|
Network No.*2 | 1 |
| |
Total Stations | 2 |
| |
|
|
|
|
Group No. |
| 0 (Fixed) |
|
|
|
|
|
Station No. | 1 |
| |
|
|
|
|
Mode*3 |
| Online |
|
Network Range | Same as the following setting |
| |
|
| ||
Assignment |
|
| |
|
| ||
|
|
| |
|
|
|
|
Refresh Parameters |
|
|
|
|
|
|
|
Interrupt Setting |
| (Use default value) |
|
|
|
| |
Interlink transmission |
|
|
|
parameters |
|
|
|
|
|
|
|
| Same as the following setting |
| |
Routing parameters |
|
| |
|
| ||
|
|
| |
|
|
|
|
| : Necessary : As necessary | : Not necessary |
(2) [Controller Setting] of GT Designer3
Item | Set value |
Network type | CC IE Control extended mode |
|
|
Network No. | 1: Network No.1 |
|
|
Station No. | 2: Station No.2 |
|
|
Mode | Online (auto. reconnection) |
|
|
Retry | 3times (Use default value) |
|
|
Timeout Time | 3sec (Use default value) |
|
|
Delay Time | 1ms (Use default value) |
|
|
Refresh Interval | High (Use default value) |
|
|
Monitor Speed | High (Use default value) |
|
|
POINT
(1)Network type of the GOT side
When the network is in the extended mode, be sure to set the network type of the GOT side to [CC IE Control extended mode].
For [Controller Setting], of GT Designer3, refer to the following.
11.3.1 Setting communication interface (Communication settings)
(2)Network type of the PLC side
Only GX Works2 can set [CC IE Control extended mode (control station)] or [CC IE Control extended mode (ordinary station)]. The CPU which is compatible with the extended mode is Universal model QCPU only.