9.2 System Configuration
9.2.1Connecting to optical loop system
| QCPU | MELSECNET/H |
|
|
| GOT | Communication driver | ||
| network module |
|
|
| |||||
|
|
|
|
|
| ||||
|
|
| Connection cable |
|
|
|
| ||
|
|
|
|
|
|
| MELSECNET/H | ||
| PLC |
| Connection cable |
| GOT |
| Number of | ||
| MELSECNET/H |
|
|
|
|
|
| ||
| Communication |
|
| Max. |
|
| connectable | ||
Model name | network module | Cable model |
| Option device | Model | ||||
| equipment | ||||||||
type | distance | ||||||||
| *1 |
|
|
| |||||
|
|
|
|
| |||||
|
|
|
|
|
|
|
| ||
QJ71LP21 |
|
|
|
|
|
|
| ||
MELSECNET/H | Optical fiber cable*2 |
| *3 |
|
| ||||
|
|
| |||||||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| 63 GOTs | ||
|
|
|
|
|
|
|
| ||
C Controller | MELSECNET/H | Optical fiber cable*2 |
| *3 |
|
| |||
module |
|
|
| ||||||
|
|
|
|
|
|
|
*1 For the system configuration of the MELSECNET/H network module, refer to the following manual.
Q corresponding MELSECNET/H Network System Reference Manual (PLC to PLC network) *2 For the optical fiber cable, refer to the following manual.
Q corresponding MELSECNET/H Network System Reference Manual (PLC to PLC network)
*3 The overall extension cable length and the length between stations vary depending on the cable type to be used and the total number of stations.
For details, refer to the following manual.
Q corresponding MELSECNET/H Network System Reference Manual (PLC to PLC network)
9.2.2Connecting to the coaxial bus systemQCPU | MELSECNET/H | GOT | Communication driver | |
network module | ||||
|
| |||
|
| Connection cable |
| |
|
|
| MELSECNET/H |
| PLC |
| Connection cable | GOT |
| Number of | ||
| MELSECNET/H |
|
|
|
|
| ||
| Communication |
| Max. |
|
| connectable | ||
Model name | Network module | Cable model | Option device | Model | ||||
equipment | ||||||||
type | distance | |||||||
| *2 |
|
|
| ||||
|
|
|
|
| ||||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| ||
*1 |
|
| Coaxial cable |
|
|
|
| |
C Controller | QJ71BR11 | MELSECNET/H | *4 |
| 31 GOTs | |||
*3 |
| |||||||
module |
|
|
|
|
|
| ||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
*1 Use a PLC CPU of function version B or a later version.
*2 For the system configuration of the MELSECNET/H network module, refer to the following manual.
Q corresponding MELSECNET/H Network System Reference Manual (PLC to PLC network) Use a MELSECNET/H network module of function version B or a later version.
9
TO CONNECTIONPLC MELSECNET/H(PLCNETWORK)
10
MELSECNET/10 CONNECTION (PLC TO PLC NETWORK)
11
12
13
14
15
CONNECTION
INVERTER
16
CONNECTION
SERVO AMPLIFIER
9. MELSECNET/H CONNECTION (PLC TO PLC NETWORK) | 9 - 7 |
9.2 System Configuration |
|