4. The detailed setting is displayed after Manufacturer, Controller Type, I/F, and Driver are set.
Make the settings according to the usage environment.
15.4.2 Communication detail settings Click the [OK] button when settings are completed.
POINT
The settings of connecting equipment can be confirmed in [I/F Communication Setting]. For details, refer to the following.
1.1.2 I/F communication setting
The Controller Setting window is displayed. Select the channel to be used from the list menu.
Select [Common] menu.
[Controller Setting] from the
1.
2.
3. Set the following items.
• Manufacturer: Mitsubishi
• Controller Type: Set according to the Controller Type to be connected.
• I/F: Interface to be used
• Driver: FREQROL 500/700
Click!
3.
4.
15.4 GOT Side Settings
15.4.1 Setting communication interface (Communication settings)
Set the channel of the connected equipment.
2.
15.4.2Communication detail settings

Make the settings according to the usage environment.

Item

Description

Range

 

Set this item when change the

9600bps,

Transmission

transmission speed used for

19200bps,

communication with the

38400bps,

Speed

connected equipment.

57600bps,

 

 

(Default: 19200bps)

115200bps

 

 

 

 

Set this item when change the

 

 

data length used for

 

Data Bit

communication with the

7bits/8bits

 

connected equipment.

 

 

(Default: 7bits)

 

 

 

 

 

Specify the stop bit length for

 

Stop Bit

communications.

1bit/2bits

 

(Default: 1bit)

 

 

 

 

 

Specify whether or not to perform

None

 

a parity check, and how it is

Parity

Even

performed during communication.

 

Odd

 

(Default: Odd)

 

 

 

 

 

 

Set the number of retries to be

 

Retry

performed when a communication

0 to 5times

timeout occurs.

 

 

 

(Default: 0time)

 

 

 

 

 

Set the time period for a

 

Timeout Time

communication to time out.

1 to 30sec

 

(Default: 3sec)

 

 

 

 

 

Set this item to adjust the

 

 

transmission timing of the

 

Delay Time

communication request from the

0 to 300ms

 

GOT.

 

 

(Default: 10ms)

 

 

 

 

POINT

(1)Communication interface setting by the Utility The communication interface setting can be changed on the Utility's [Communication Settings] after writing [Communication Settings] of project data.

For details on the Utility, refer to the following manuals.

GT User's Manual

(2)Precedence in communication settings

When settings are made by GT Designer3 or the Utility, the latest setting is effective.

15. INVERTER CONNECTION

15 - 29

9

TO CONNECTIONPLC MELSECNET/H(PLCNETWORK)

10

MELSECNET/10 CONNECTION (PLC TO PLC NETWORK)

11

CC-Link IE CONTROLLER NETWORK CONNECTION

12

CC-Link IE FIELD NETWORK CONNECTION

13

CC-Link CONNECTION (INTELLIGENT DEVICE STATION)

14

CC-Link CONNECTION (Via G4)

15

CONNECTION

INVERTER

16

CONNECTION

SERVO AMPLIFIER

15.4 GOT Side Settings