Setting item

When selecting buffer memory (G) with the following controllers

MELSEC-QnU/DC, Q17nD/M/NC/DR, CRnD-700

MELSEC-L

MELSEC-QnA/Q/QS, MELDAS C6 *

MELSEC-Q(MULTI)/Q MOTION

(For MELSEC-QnU/DC, Q17nD/M/NC/DR, CRnD-700)

(For MELSEC-FX)

 

Item

 

 

Description

 

 

Set the device name, device number, and bit number.

 

 

The bit number can be set only by specifying the bit of word device.

 

 

When setting buffer memory (BM) and (G), set the buffer memory address in the space for the device number.

 

 

 

 

 

 

 

 

 

 

Reading the device comment data created by GX Developer and confirming the device

 

 

 

 

comment/device name are available during device setting.

 

 

 

 

For details on the procedure to refer to the device comment, refer to the following.

 

 

 

 

 

GT Designer3 Version Screen Design Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

Block

 

Set the block number of the extended file register.

 

 

 

This item can be set only when the extended file register (ER) is selected.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set when the buffer memory (BM) is selected.

Device

 

Intelligent

Unit top I/O

Set the head I/O number of the buffer memory for the intelligent function module.

 

 

Set the first 2 digits of the 3-digit head I/O number.

 

 

 

 

 

function

 

 

 

 

 

 

 

 

 

Set when the buffer memory (G) is selected.

 

 

module

 

 

 

Unit No.

Set the head I/O number of the buffer memory for the intelligent function module.

 

 

 

 

 

 

 

Set the first 2 digits of the 3-digit head I/O number.

 

 

 

 

 

 

 

 

 

 

Set for using the buffer memory of MELSEC-FX series.

 

 

 

Mask type

Set the mask type for monitoring or writing only specified bits of the buffer memory.

 

 

 

 

 

 

 

MELSEC-

 

 

(4) Setting of the mask type (MELSEC-FX)

 

 

FX buffer

 

 

 

 

 

 

Set for using the buffer memory of MELSEC-FX series.

 

 

memory

 

 

 

 

Set the module No. of the special function unit or special function block to monitor or write.

 

 

 

Unit No.

 

 

 

 

 

(5) Setting of the module No. (MELSEC-FX)

 

Information

Displays the device type and its setting range selected in [Device].

 

 

 

 

 

 

 

 

Set the station number of the controller to be monitored.

 

 

 

 

 

 

 

 

 

CPU No.

Set the CPU No. of the controller.

 

 

 

 

(1) Setting of the CPU No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Network

Host

Select this item for monitoring the host controller.

 

 

 

 

 

 

 

 

Select this for monitoring other controllers.

 

 

 

 

 

 

 

 

After selecting the item, set the station number and network number of the controller to be

 

 

 

Other

monitored.

 

 

 

 

 

NW No.: Set the network No.

 

 

 

 

 

Station No.: Set the station No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. DEVICE RANGE THAT CAN BE SET

2 - 3

1

PREPARATORYFORPROCEDURESMONITORING 2

RANGESETBE

DEVICE CANTHAT 3

RANGEACCESS MONITORINGFOR 4

MONITORTOREDUNTANTSYSTEM HOW 5

CONNECTIONBUS 6

DIRECTTOCONNECTIONCPU 7

LINKCOMPUTER CONNECTION 8

ETHERNETCONNECTION