8.4 PLC Side Setting

 

Model

Reference

 

Q03UDECPU, Q04UDEHCPU,

 

 

Q06UDEHCPU, Q10UDEHCPU,

 

Built-in Ethernet

Q13UDEHCPU, Q20UDEHCPU,

8.4.1

Q26UDEHCPU, Q50UDEHCPU,

port QCPU

8.4.2

Q100UDEHCPU, Q03UDVCPU,

 

 

 

Q04UDVCPU, Q06UDVCPU,

 

 

Q13UDVCPU, Q26UDVCPU

 

 

 

 

C Controller

Q12DCCPU-V

8.4.4

module

Q24DHCCPU-V

 

 

 

 

 

L02CPU

 

Built-in Ethernet

L26CPU

8.4.1

L26CPU-BT

port LCPU

8.4.2

L02CPU-P

 

 

 

L26CPU-PBT

 

 

 

 

Ethernet module

QJ71E71-100, QJ71E71-B5,

 

(Q Series)

QJ71E71-B2, QJ71E71

8.4.3

 

 

Ethernet module

LJ71E71-100

 

(L Series)

 

 

 

 

 

 

 

AJ71QE71N3-T,

 

 

AJ71QE71N-B5,

 

 

AJ71QE71N-B2, AJ71QE71N-T,

 

 

AJ71QE71N-B5T,

 

Ethernet module

AJ71QE71, AJ71QE71-B5,

 

A1SJ71QE71N3-T,

8.4.5

(QnA Series)

A1SJ71QE71N-B5,

 

 

 

 

A1SJ71QE71N-B2, A1SJ71QE71N-T,

 

 

A1SJ71QE71N-B5T,

 

 

A1SJ71QE71-B5,

 

 

A1SJ71QE71-B2

 

 

 

 

 

AJ71E71N3-T, AJ71E71N-B5,

 

 

AJ71E71N-B2, AJ71E71N-T,

 

 

AJ71E71N-B5T, AJ71E71-S3,

 

 

A1SJ71E71N3-T,

 

Ethernet module

A1SJ71E71N-B5,

8.4.6

(A Series)

A1SJ71E71N-B2,

 

 

A1SJ71E71N-T,

 

 

A1SJ71E71N-B5T,

 

 

A1SJ71E71-B5-S3,

 

 

A1SJ71E71-B2-S3

 

 

 

 

Ethernet module

FX3U-ENET, FX3U-ENET-ADP

8.4.7

(FX Series)

 

 

 

 

 

CNC C70

Q173NCCPU

8.4.8

 

 

 

8.4.1Connecting to Built-in Ethernet port CPU (one-to-one connection)

This section describes the settings of the GOT and Built-in Ethernet port CPU in the following case of system configuration.

POINT

Connecting to Built-in Ethernet port CPU

For details of Built-in Ethernet port CPU, refer to the following manual.

QnUCPU User's Manual (Communication via Built-in Ethernet Port)

MELSEC-L CPU Module User's Manual (Built- In Ethernet Function)

System configuration

For connecting one Built-in Ethernet port QCPU to one GOT, the PLC side settings are not required. Set [Ethernet] for [Controller Setting] on GT Designer3, and then connect Built-in Ethernet port QCPU to the GOT.

[Controller Setting] and [Ethernet] of GT

Designer3

<GOT>

(The settings other than the following are set to the default)

Network No.

: 1

PLC No.

: 1

IP address

: 192.168.3.1

Port No.

: 5001

Communication : UDP (fixed) format

<Connecting to Built-in Ethernet port CPU> *1 (The following settings are set to the default)

Network No.

: 1 (virtual)*2

PLC No.

: 2 (virtual)*2

IP address

: 192.168.3.39

Port No.

: 5006 (fixed)

Communication : UDP (fixed) format

*1 For the settings when using system devices including a hub and a transceiver, refer to the following.

8.4.2 Connecting to Built-in Ethernet port CPU (multiple connection)

*2 These setting items do not exist at the PLC side. However, the virtual values must be set on the GOT side.

[Controller Setting] and [Ethernet] of GT Designer3

8 - 20

8. ETHERNET CONNECTION

 

8.4 PLC Side Setting