When connecting to MELSEC-FX

PLC CPU

Ethernet

GOT

Communication driver

module

 

 

 

 

 

Connection cable

 

Ethernet (FX), Gateway

 

PLC

 

Connection cable*1

Maximum

GOT

 

Number of

Model name

Ethernet module

Communication

Cable model

segment

Option device

Model

connectable

*4*5

type

length*3

equipment

 

 

 

 

 

 

*2

 

MELSEC-FX

FX3U-ENET

Ethernet

 

100m

- (Built into GOT)

*7

 

 

 

 

 

(FX3U, FX3G)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GT15-J71E71-100

 

2 GOTs

 

 

 

 

 

 

 

 

 

 

 

 

 

*2

 

 

 

 

 

 

 

 

FX3UC-1PS-5V,

 

 

 

- (Built into GOT)

*7

 

MELSEC-FX

FX2NC-CNV-IF

Ethernet

 

100m

 

 

 

 

 

(FX3UC, FX3GC)

+

 

 

 

 

 

 

 

 

 

 

 

FX3U-ENET*6

 

Twisted pair cable

 

 

 

 

 

 

 

GT15-J71E71-100

 

 

 

 

 

 

 

 

 

 

 

10BASE-T

 

 

 

 

 

 

 

 

 

*2

 

 

FX3U-CNV-BD,

 

Shielded twisted pair

 

 

 

 

 

 

 

 

 

MELSEC-FX

FX3U-422-BD,

 

cable (STP) or unshielded

 

- (Built into GOT)

*7

 

FX3U-232-BD,

Ethernet

twisted pair cable (UTP):

100m

 

 

 

 

 

(FX3U)

 

 

 

+

 

Category 3, 4, and 5

 

 

 

 

 

 

 

 

 

 

 

FX3U-ENET-ADP*8*9

 

100BASE-TX

 

 

 

 

 

 

 

GT15-J71E71-100

 

 

 

 

 

Shielded twisted pair

 

 

 

 

 

 

 

 

 

 

 

 

 

cable (STP):

 

 

*2

 

 

 

 

Category 5 and 5e

 

- (Built into GOT)

*7

 

MELSEC-FX

FX3U-ENET-ADP

Ethernet

 

100m

 

 

 

 

4 GOTs

(FX3UC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GT15-J71E71-100

 

 

 

 

 

 

 

 

 

 

 

FX3G-CNV-ADP,

 

 

 

 

*2

 

MELSEC-FX

 

 

 

 

 

 

+

Ethernet

 

 

- (Built into GOT)

*7

 

(FX3G)

 

 

 

FX3U-ENET-ADP*9

 

 

100m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MELSEC-FX

FX3U-ENET-ADP*9

Ethernet

 

 

GT15-J71E71-100

 

 

(FX3GC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1 The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system. Connect to the Ethernet module, hub, transceiver or other system equipment corresponding to the applicable Ethernet network system.

Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standard. A cross cable is available for connecting the GOT to the Ethernet module.

*2 When connecting GT16 of the function version A to an equipment that meets the 10BASE (-T/2/5) standard, use the switching hub and operate in a 10Mbps/100Mbps mixed environment.

For how to check the function version, refer to the following. GT16 User's Manual (Hardware)

*3 A length between a hub and a node.

The maximum distance differs depending on the Ethernet device to be used.

The following shows the number of the connectable nodes when a repeater hub is used.

10BASE-T: Max. 4 nodes for a cascade connection (500m)

100BASE-TX: Max. 2 nodes for a cascade connection (205m)

When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of cascades.

For the limit, contact the switching hub manufacturer.

*4 For the system configuration of the Ethernet module, refer to the following manuals.

For FX Ethernet Interface Module User’s Manual

*5 Select one of the following [Controller Type] in [Ethernet] of GT Designer3.

• Ethernet module (FX Series): FX

For [Ethernet] of GT Designer3, refer to the following. 8.3.3 Ethernet setting

1

PREPARATORYFORPROCEDURESMONITORING 2

RANGESETBE

DEVICE CANTHAT 3

RANGEACCESS MONITORINGFOR 4

MONITORTOREDUNTANTSYSTEM HOW 5

CONNECTIONBUS 6

DIRECTTOCONNECTIONCPU 7

LINKCOMPUTER CONNECTION 8

ETHERNETCONNECTION

8. ETHERNET CONNECTION

8 - 9

8.2 System Configuration