(7)
|
|
|
|
| Device |
| Device name*2 | Setting range | No. | ||
| represen | ||||
|
|
|
|
| |
|
|
|
|
| tation |
| Servo amplifier request (SP) | SP0 | to | SP6 |
|
Bit device |
|
|
|
|
|
Operation mode selection | OM0 | to | OM4 |
| |
(OM) |
| ||||
|
|
|
| ||
|
|
|
|
| |
Instruction demand | TMB1 | to | TMB6 |
| |
| (for test operation) (TMB) |
| |||
|
|
|
|
| |
|
|
|
|
|
|
| Basic setting parameter | PA1 | to | PA19 |
|
| (PA)*1 | PA1001 | to | PA1019 |
|
| Gain filter parameter | PB1 | to | PB45 |
|
| (PB)*1 | PB1001 | to | PB1045 |
|
| Extension setting parameter | PC1 | to | PC50 |
|
| (PC)*1 | PC1001 | to | PC1050 |
|
| I/O setting parameter (PD)*1 | PD1 | to | PD30 |
|
| PD1001 | to | PD1030 |
| |
|
|
| |||
|
|
|
|
| Decimal |
device | Status display (ST)*3 | ST0 | to | ST14 | |
| AL11 | to | AL25 |
| |
|
| AL0 | to | AL1 |
|
Word | Alarm (AL)*3 | AL200 | to | AL205 |
|
| AL210 | to | AL215 |
| |
|
| AL230 | to | AL235 |
|
|
|
|
|
|
|
| External input (DI)*4 | DI0 | to | DI2 |
|
| External output (DO)*3 | DO0 | to | DO1 |
|
| Input signal for test operation | TMI0 |
|
|
|
| (for test operation) (TMI) |
|
|
| |
|
|
|
|
| |
|
|
|
|
|
|
| Forced output of signal pin | TMO0 |
|
|
|
| (for test operation) (TMO) |
|
|
| |
|
|
|
|
| |
|
|
|
|
|
|
| Set data | TMD0 | to | TMD1 |
|
| (for test operation) (TMD) | TMD3 |
|
|
|
|
|
|
|
|
|
*1 1 to 50 of PA, PB, PC, and PD are used when writing data to the servo amplifier RAM.
1001 to 1050 of PA, PB, PC, and PD are used when writing
data to E2PROM of the servo amplifier.
*2 The GOT cannot read or write data from/to consecutive devices.
*3 Only reading is possible.
*4 Only reading is possible for DI0 to DI1.
POINT
Precautions for SP, OM, TMB, TMI, TMO, and TMD devices
(1)For bit devices
Only writing is possible.
[Alternate] of a bit switch cannot be used. Use [Set], [Reset], and [Momentary] of a bit switch.
(2)For word devices
Only writing is possible. Numerical input cannot be used.
When writing, use [Word Set] of a data set switch.
The following shows correspondences between virtual devices for servo amplifier and data of the servo amplifier used with the GOT.
(a) Servo amplifier request
Device | Item | Symbol | |
name | |||
|
| ||
SP0 | Status display data clear | ― | |
SP1 | Current alarm clear | ― | |
|
|
| |
SP2 | Alarm history clear | ― | |
|
|
| |
SP3 | External input signal prohibited | ― | |
SP4 | External output signal prohibited | ― | |
|
|
| |
SP5 | External input signal resumed | ― | |
|
|
| |
SP6 | External output signal resumed | ― |
(b) Operation mode selection
Device | Item | Symbol | |
name | |||
|
| ||
OM0 | Normal mode (not test operation mode) | ― | |
OM1 | JOG operation | ― | |
OM2 | Positioning operation | ― | |
|
|
| |
OM3 | Motorless operation | ― | |
|
|
| |
OM4 | Output signal (DO) forced output | ― |
(c) Instruction demand (for test operation)
Device | Item | Symbol | |
name | |||
|
| ||
TMB1 | Temporary stop command | ― | |
TMB2 | Test operation (positioning operation) start | ― | |
command | |||
|
| ||
|
|
| |
TMB3 | Forward rotation direction | ― | |
|
|
| |
TMB4 | Reverse rotation direction | ― | |
TMB5 | Restart for remaining distance | ― | |
|
|
| |
TMB6 | Remaining distance clear | ― |
(d) Basic parameter/expansion parameter
Device name | Item | Symbol*1 | |
PA1, PA1001 | Control mode | *STY | |
PA2, PA1002 | Regenerative brake option | *REG | |
|
|
| |
PA3, PA1003 | Absolute position detection | *ABS | |
system | |||
|
| ||
|
|
| |
PA4, PA1004 | Function selection | *AOP1 | |
|
|
| |
PA5, PA1005 | Number of command input | *FBP | |
pulses per revolution | |||
|
| ||
|
|
| |
| Electronic gear numerator |
| |
PA6, PA1006 | (command pulse multiplying | CMX | |
| factor numerator) |
| |
|
|
| |
| Electronic gear denominator |
| |
PA7, PA1007 | (command pulse multiplying | CDV | |
| factor denominator) |
| |
|
|
| |
PA8, PA1008 | Auto tuning mode | ATU | |
|
|
| |
PA9, PA1009 | Auto tuning response | RSP | |
|
|
| |
PA10, PA1010 | INP | ||
PA11, PA1011 | Forward torque limit | TLP | |
|
|
| |
PA12, PA1012 | Reverses torque limit | TLN | |
|
|
| |
PA13, PA1013 | Command pulse input form | *PLSS | |
PA14, PA1014 | Rotation direction selection | *POL | |
|
|
| |
PA15, PA1015 | Encoder output pulses | *ENR | |
|
|
| |
PA16 to PA18, | For manufacturer setting | ― | |
PA1016 to PA1018 | |||
|
| ||
|
|
| |
PA19, PA1019 | Parameter block | *BLK |
*1 For the parameters prefixed by an asterisk (*), setting becomes effective when the power is turned off once and back on after setting the parameter data.
9
TO CONNECTIONPLC MELSECNET/H(PLCNETWORK)
10
MELSECNET/10 CONNECTION (PLC TO PLC NETWORK)
11
12
13
14
15
CONNECTION
INVERTER
16
CONNECTION
SERVO AMPLIFIER
16. SERVO AMPLIFIER CONNECTION | 16 - 31 |
16.6 Device Range that Can Be Set |
|