17

When connecting the GOT and PC with Ethernet (For GT16, GT15, GT14, GT12)

Communication driver

PLC

GOT

PC

Connection type dependant

Connection cable

Varies according to the connection type.

 

PLC

 

 

GOT

Connection cable*1

Maximum

Personal

Number of

 

 

 

computer

 

 

 

 

 

 

segment

connectable

 

Connection type

Model

 

Interface

Cable model

length*3

Software

equipment

For the system configuration

*2

*5

- (Built into GOT)

Twisted pair cable

 

 

 

between

 

 

10BASE-T

 

 

 

the GOT and PLC, refer to

 

 

 

Shielded twisted pair cable

 

 

 

the following.

 

 

 

(STP) or unshielded

 

 

1 personal

 

 

 

 

 

twisted pair cable (UTP):

 

 

 

 

 

 

 

100m

MT Works2

computer

 

BUS

 

 

 

Category 3, 4, and 5

 

 

 

 

 

 

for 1 GOT

 

 

 

GT15-J71E71-100

100BASE-TX

 

 

CONNECTION*4

 

 

 

 

 

 

 

Shielded twisted pair cable

 

 

 

 

 

 

 

 

 

 

 

 

DIRECT

 

 

 

(STP):

 

 

 

CONNECTION TO CPU

 

 

 

Category 5 and 5e

 

 

 

 

 

 

 

 

 

 

 

 

*1 The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system. Connect to the Ethernet module, hub, transceiver, or other system equipment corresponding to the applicable Ethernet network system.

Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standards. A cross cable is available for connecting the GOT to the Ethernet module.

*2 When connecting GT16 of the function version A to an equipment that meets the 10BASE (-T/2/5) standard, use the switching hub and operate in a 10Mbps/100Mbps mixed environment.

For how to check the function version, refer to the following.

GT16 User's Manual

*3 A length between a hub and a node.

The maximum distance differs depending on the Ethernet device to be used.

The following shows the number of the connectable nodes when a repeater hub is used.

10BASE-T: Max. 4 nodes for a cascade connection (500m)

100BASE-TX: Max. 2 nodes for a cascade connection (205m)

When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of cascades.

For the limit, contact the switching hub manufacturer.

*4 LCPU is not applicable to the bus connection.

*5 GT14 models compatible with Ethernet connection are only GT1455-QTBDE and GT1450-QLBDE.

ROBOT CONTROLLER CONNECTION

18

CNC CONNECTION

19

CONNECTION

GOT MULTI-DROP

20

MULTIPLE-GT14, GT12, GT11, GT10 CONNECTION FUNCTION

21

FUNCTION

MULTI-CHANNEL

22

FUNCTION

FA TRANSPARENT

22. FA TRANSPARENT FUNCTION

22 - 31

22.4 System Configuration