13.3 GOT Side Settings

13.3.1 Setting communication interface (Communication

settings)

POINT

 

9

TO CONNECTIONPLC MELSECNET/H(PLCNETWORK)

Set the channel of the connected equipment.

2.

3.

4.

The settings of connecting equipment can be confirmed in [I/F Communication Setting].

For details, refer to the following. 1.1.2 I/F communication setting

13.3.2Communication detail settings

Make the settings according to the usage environment.

(1) CC-Link Ver.2 (ID)

10

MELSECNET/10 CONNECTION (PLC TO PLC NETWORK)

11

CC-Link IE CONTROLLER NETWORK CONNECTION

12

Click!

1. Select [Common] [Controller Setting] from the menu.

2. The Controller Setting window is displayed. Select the channel to be used from the list menu.

3. Set the following items.

Manufacturer: Mitsubishi

Controller Type: Set according to the Controller Type to be connected.

I/F: Interface to be used

Driver:

When MODEL GT15-J61BT13 CC-Link communication unit is used

CC-Link Ver2 (ID)

When MODEL GT15-75J61BT13-Z CC-Link communication unit is used

CC-Link (ID)

4.The detailed setting is displayed after Manufacturer, Controller Type, I/F, and Driver are set.

Make the settings according to the usage environment.

13.3.2 Communication detail settings

Click the [OK] button when settings are completed.

Item

Description

Range

Station No.

Set the station No. of the GOT.

1 to 64

(Default: 1)

 

 

 

 

 

Transmission

Set the transmission speed and

 

the mode of the GOT.

0 to E

Rate*1

(Default: 0)

 

 

 

 

 

 

Mode

Set the mode of CC-Link.

Ver.1/Ver.2/

(Default: Ver.1)

Additional/Offline

 

 

 

 

Expanded

Set the cyclic point expansion.

Single/Double/

Cyclic

(Default: Single)

Quadruple/Octuple

 

 

 

Occupied

Set the number of stations

 

occupied by the GOT.

1 Station/4 Stations

Station

(Default: 1 Station)

 

 

 

 

 

 

Input for Error

Set Clear/Hold at an error

 

occurrence.

Clear/Hold

Station

(Default: Clear)

 

 

 

 

 

 

 

Set the number of retries to be

 

 

performed when a communication

 

 

timeout occurs.

 

Retry

When no response is received

0 to 5times

 

after retries, a communication

 

 

times out.

 

 

(Default: 3times)

 

 

 

 

 

Set the time period for a

 

Timeout Time

communication to time out.

3 to 90sec

 

(Default: 3sec)

 

 

 

 

 

Set the delay time for reducing the

 

Delay Time

load of the network/destination

0 to 300 (ms)

PLC.

 

 

 

(Default: 0ms)

 

 

 

 

CC-Link IE FIELD NETWORK CONNECTION

13

CC-Link CONNECTION (INTELLIGENT DEVICE STATION)

14

CC-Link CONNECTION (Via G4)

15

CONNECTION

INVERTER

16

CONNECTION

SERVO AMPLIFIER

13. CC-Link CONNECTION (INTELLIGENT DEVICE STATION)

13 - 9

13.3 GOT Side Settings