17.ROBOT CONTROLLER CONNECTION

17.1Connectable Model List

The following table shows the connectable models.

Series

Model name

Clock

Communication

Refer to

type

 

 

 

 

Robot

CRnD-700

 

Ethernet

17.2.1

controller

 

 

 

 

 

For details on the connection with CRnQ-700 (Q172DRCPU), refer to Mitsubishi Products (Chapter 5 to 13).

17.2System Configuration

17.2.1Connecting to robot controller (CRnD-700)

 

Robot

 

GOT

 

 

 

 

controller

 

 

Communication driver

 

 

 

 

 

 

Connection cable

 

 

 

 

 

 

 

 

 

Ethernet(MELSEC),Q17nNC,CRnD-700

Robot controller

Connection cable

Maximum

GOT

 

Number of connectable

 

Communication

segment

 

 

Model name

*1*2

Option device

Model

equipment

type

length*3

 

 

 

 

 

 

 

Twisted pair cable

 

- (Built into GOT)

*3

 

 

 

10BASE-T

 

 

 

 

 

Shielded twisted pair cable (STP) or

 

 

 

 

CRnD-700*5*6

Ethernet

unshielded twisted pair cable (UTP):

100m

 

 

1 GOT

Category 3, 4, and 5

 

 

 

 

 

 

 

 

 

 

100BASE-TX

 

GT15-J71E71-100

 

 

Shielded twisted pair cable (STP):

Category 5 and 5e

*1 The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system. Connect to the Ethernet module, hub, transceiver or other system equipment corresponding to the applicable Ethernet network system.

Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standard.

*2 A straight cable is available.

When connecting QnUDE(H) and GOT directly with Ethernet cable, remember that the by cross cable is available.

*3 When connecting GT16 of the function version A to an equipment that meets the 10BASE (-T/2/5) standard, use the switching hub and operate in a 10Mbps/100Mbps mixed environment.

For how to check the function version, refer to the following.

GT16 User's Manual (Hardware) *4 A length between a hub and a node.

The maximum distance differs depending on the Ethernet device to be used.

The following shows the number of the connectable nodes when a repeater hub is used.

10BASE-T: Max. 4 nodes for a cascade connection (500m)

100BASE-TX: Max. 2 nodes for a cascade connection (205m)

When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of cascades.

For the limit, contact the switching hub manufacturer.

*5 For the system configuration of CRnD-700, refer to the following manual.

CRnD-700 SET UP MANUAL

*6 Select [CRnD-700] for [Controller Type] in [Ethernet] of GT Designer3. For [Ethernet] of GT Designer3, refer to the following.

17.3.3 Ethernet setting

17 - 2

17. ROBOT CONTROLLER CONNECTION

 

17.1 Connectable Model List