Device name | Item | Symbol*1 | |
PRM24, PRM1024 | Zero speed | ZSP | |
PRM25 to PRM26, | For manufacturer setting | ― | |
PRM1025 to PRM1026 | |||
|
| ||
|
|
| |
PRM27, PRM1027 | Encoder output pulses | *ENR | |
|
|
| |
PRM28, PRM1028 | Internal torque limit 1 | TL1 | |
|
|
| |
PRM29 to PRM32, | For manufacturer setting | ― | |
PRM1029 to PRM1032 | |||
|
| ||
|
|
| |
PRM33, PRM1033 | Electromagnetic brake | MBR | |
sequence output | |||
|
| ||
|
|
| |
| Ratio of load inertia moment |
| |
PRM34, PRM1034 | to servo motor inertia | GD2 | |
| moment |
| |
|
|
| |
PRM35, PRM1035 | Position loop gain 2 | PG2 | |
|
|
| |
PRM36, PRM1036 | Speed loop gain 1 | VG1 | |
|
|
| |
PRM37, PRM1037 | Speed loop gain 2 | VG2 | |
|
|
| |
PRM38, PRM1038 | Speed integral | VIC | |
compensation | |||
|
| ||
|
|
| |
PRM39, PRM1039 | Speed differential | VDC | |
compensation | |||
|
| ||
|
|
| |
PRM40 to PRM41, | For manufacturer setting | ― | |
PRM1040 to PRM1041 | |||
|
| ||
|
|
| |
PRM42, PRM1042 | Input signal selection 1 | *DI1 | |
|
|
| |
PRM43 to PRM50, | For manufacturer setting | ― | |
PRM1043 to PRM1050 | |||
|
| ||
|
|
| |
PRM51, PRM1051 | Function selection 6 | *OP6 | |
|
|
| |
PRM52 to PRM53, | For manufacturer setting | ― | |
PRM1052 to PRM1053 | |||
|
| ||
|
|
| |
PRM54, PRM1054 | Function selection 9 | *OP9 | |
|
|
| |
PRM55, PRM1055 | Function selection A | *OPA | |
|
|
| |
PRM56 to PRM57, | For manufacturer setting | ― | |
PRM1056 to PRM1057 | |||
|
| ||
|
|
| |
PRM58, PRM1058 | Machine resonance | NH1 | |
suppression filter 1 | |||
|
| ||
|
|
| |
PRM59, PRM1059 | Machine resonance | NH2 | |
suppression filter 2 | |||
|
| ||
|
|
| |
|
| ||
PRM60, PRM1060 | adaptive vibration | LPF | |
| suppression control |
| |
|
|
| |
| Ratio of load inertia moment |
| |
PRM61, PRM1061 | to servo motor inertia | GD2B | |
| moment 2 |
| |
|
|
| |
PRM62, PRM1062 | Position control gain 2 | PG2B | |
changing ratio | |||
|
| ||
|
|
| |
PRM63, PRM1063 | Speed control gain 2 | VG2B | |
changing ratio | |||
|
| ||
|
|
| |
PRM64, PRM1064 | Speed integral compensation | VICB | |
changing ratio | |||
|
| ||
|
|
| |
PRM65, PRM1065 | Gain changing selection | *CDP | |
|
|
| |
PRM66, PRM1066 | Gain changing condition | CDS | |
|
|
| |
PRM67, PRM1067 | Gain changing time constant | CDT | |
|
|
| |
PRM68, PRM1068 | For manufacturer setting | ― | |
|
|
| |
PRM69, PRM1069 | Command pulse multiplying | CMX2 | |
factor numerator 2 | |||
|
| ||
|
|
| |
PRM70, PRM1070 | Command pulse multiplying | CMX3 | |
factor numerator 3 | |||
|
| ||
|
|
| |
PRM71, PRM1071 | Command pulse multiplying | CMX4 | |
factor numerator 4 | |||
|
| ||
|
|
| |
PRM72 to PRM75, | For manufacturer setting | ― | |
PRM1072 to PRM1075 | |||
|
| ||
|
|
| |
PRM76, PRM1076 | Internal torque limit 2 | TL2 | |
PRM77 to PRM84, | For manufacturer setting | ― | |
PRM1077 to PRM1084 | |||
|
| ||
|
|
|
*1 For the parameters prefixed by an asterisk (*), setting becomes effective when the power is turned off once and back on after setting the parameter data.
(e) Status display |
| ||
|
|
|
|
| Device name | Item | Symbol |
| ST0 | Cumulative feedback pulses | ― |
|
|
|
|
| ST1 | Servo motor speed | ― |
|
|
|
|
| ST2 | Droop pulses | ― |
|
|
|
|
| ST3 | Cumulative command pulses | ― |
|
|
|
|
| ST4 | Command pulse frequency | ― |
|
|
|
|
| ST5 | Effective load ratio | ― |
|
|
|
|
| ST6 | Peak load ratio | ― |
|
|
|
|
| ST7 | Instantaneous torque | ― |
|
|
|
|
| ST8 | Within | ― |
|
|
|
|
| ST9 | ABS counter | ― |
|
|
|
|
| ST10 | Load inertia moment ratio | ― |
|
|
|
|
(f) Alarm
Device | Item | Symbol | |
name | |||
|
| ||
AL0 | Current alarm number | ― | |
|
|
| |
AL11 | Servo status when alarm occurs cumulative | ― | |
feedback pulses | |||
|
| ||
|
|
| |
AL12 | Servo status when alarm occurs | ― | |
servo motor speed | |||
|
| ||
|
|
| |
AL13 | Servo status when alarm occurs droop | ― | |
pulses | |||
|
| ||
|
|
| |
AL14 | Servo status when alarm occurs cumulative | ― | |
command pulses | |||
|
| ||
|
|
| |
AL15 | Servo status when alarm occurs command | ― | |
pulse frequency | |||
|
| ||
|
|
| |
AL16 | Servo status when alarm occurs effective | ― | |
load ratio | |||
|
| ||
|
|
| |
AL17 | Servo status when alarm occurs peak load | ― | |
ratio | |||
|
| ||
|
|
| |
AL18 | Servo status when alarm occurs | ― | |
instantaneous torque | |||
|
| ||
|
|
| |
AL19 | Servo status when alarm occurs within one- | ― | |
revolution position | |||
|
| ||
|
|
| |
AL20 | Servo status when alarm occurs ABS | ― | |
counter | |||
|
| ||
|
|
| |
AL21 | Servo status when alarm occurs | ― | |
load inertia moment ratio | |||
|
| ||
|
|
| |
AL200 | Alarm number from alarm history | ― | |
most recent alarm | |||
|
| ||
|
|
| |
AL201 | Alarm number from alarm history | ― | |
first alarm in past | |||
|
| ||
|
|
| |
AL202 | Alarm number from alarm history | ― | |
second alarm in past | |||
|
| ||
|
|
| |
AL203 | Alarm number from alarm history | ― | |
third alarm in past | |||
|
| ||
|
|
| |
AL204 | Alarm number from alarm history | ― | |
fourth alarm in past | |||
|
| ||
|
|
| |
AL205 | Alarm number from alarm history | ― | |
fifth alarm in past | |||
|
| ||
|
|
| |
AL210 | Alarm occurrence time in alarm history | ― | |
most recent alarm | |||
|
| ||
|
|
| |
AL211 | Alarm occurrence time in alarm history | ― | |
first alarm in past | |||
|
| ||
|
|
| |
AL212 | Alarm occurrence time in alarm history | ― | |
second alarm in past | |||
|
| ||
|
|
| |
AL213 | Alarm occurrence time in alarm history | ― | |
third alarm in past | |||
|
| ||
|
|
| |
AL214 | Alarm occurrence time in alarm history | ― | |
fourth alarm in past | |||
|
| ||
|
|
|
9