15.5.12 Station number setting

Set each station number so that no station number overlaps.

The station number can be set without regard to the cable connection order. There is no problem even if station numbers are not consecutive.

Station

Station

Station

Station

Station

No.3

No.0

No.1

No.21

No.6

GOT

Examples of station number setting

(1)Direct specification

When setting the device, specify the station number of the inverter of which data is to be changed.

Specification range

0 to 31

(2)Indirect specification

When setting the device, indirectly specify the station number of the inverter of which data is to be changed using the 16-bit GOT internal data register (GD10 to GD25).

When specifying the station No. from 100 to 155 on GT Designer3, the value of GD10 to GD25 compatible to the station No. specification will be the station No. of the inverter.

Specification

Compatible

Setting range

station NO.

device

 

100

GD10

 

 

 

 

101

GD11

 

 

 

 

102

GD12

 

 

 

 

103

GD13

 

 

 

 

104

GD14

 

 

 

 

105

GD15

 

 

 

 

106

GD16

0 to 31

 

 

107

GD17

For the setting other than the above,

 

 

108

GD18

error (dedicated device is out of range)

will occur.

 

 

109

GD19

 

 

 

 

110

GD20

 

 

 

 

111

GD21

 

 

 

 

112

GD22

 

 

 

 

113

GD23

 

 

 

 

114

GD24

 

 

 

 

115

GD25

 

 

 

 

9

TO CONNECTIONPLC MELSECNET/H(PLCNETWORK)

10

MELSECNET/10 CONNECTION (PLC TO PLC NETWORK)

11

CC-Link IE CONTROLLER NETWORK CONNECTION

12

CC-Link IE FIELD NETWORK CONNECTION

13

CC-Link CONNECTION (INTELLIGENT DEVICE STATION)

14

CC-Link CONNECTION (Via G4)

15

CONNECTION

INVERTER

16

CONNECTION

SERVO AMPLIFIER

15. INVERTER CONNECTION

15 - 43

15.5 FREQROL Series Inverter Side Settings