(g) I/O setting parameter
Device name | Item | Symbol*1 | |
PD1, PD1001 | Input signal automatic ON | *DIA1 | |
selection 1 | |||
|
| ||
|
|
| |
PD2, PD1002 | For manufacturer setting | ― | |
|
|
| |
PD3, PD1003 | Input signal device selection 1 | *DI1 | |
|
| ||
|
|
| |
PD4, PD1004 | Input signal device selection 2 | *DI2 | |
|
| ||
|
|
| |
PD5, PD1005 | Input signal device selection 3 | *DI3 | |
|
| ||
|
|
| |
PD6, PD1006 | Input signal device selection 4 | *DI4 | |
|
| ||
|
|
| |
PD7, PD1007 | Input signal device selection 5 | *DI5 | |
|
| ||
|
|
| |
PD8, PD1008 | Input signal device selection 6 | *DI6 | |
|
| ||
|
|
| |
PD9, PD1009 | For manufacturer setting | ― | |
|
|
| |
PD10, D1010 | Input signal device selection 8 | *DI8 | |
|
| ||
|
|
| |
PD11, PD1011 | Input signal device selection 9 | *DI9 | |
|
| ||
|
|
| |
PD12, PD1012 | Input signal device selection 10 | *DI10 | |
|
| ||
|
|
| |
PD13, PD1013 | Output signal device selection 1 | *DO1 | |
|
| ||
|
|
| |
PD14, PD1014 | Output signal device selection 2 | *DO2 | |
|
| ||
|
|
| |
PD15, PD1015 | Output signal device selection 3 | *DO3 | |
|
| ||
|
|
| |
PD16, PD1016 | Output signal device selection 4 | *DO4 | |
|
| ||
|
|
| |
PD17, PD1017 | For manufacturer setting | ― | |
|
|
| |
PD18, PD1018 | Output signal device selection 6 | *DO6 | |
|
| ||
|
|
| |
PD19, PD1019 | Response level setting | *DIF | |
|
|
| |
PD20, 1020 | Function selection | *DOP1 | |
|
|
| |
PD21, PD1021 | For manufacturer setting | ― | |
|
|
| |
PD22, PD1022 | Function selection | *DOP3 | |
|
|
| |
PD23, PD1023 | For manufacturer setting | ― | |
|
|
| |
PD24, PD1024 | Function selection | *DOP5 | |
|
|
| |
PD25 to PD30, | For manufacturer setting | ― | |
PD1025 to PD1030 | |||
|
| ||
|
|
|
*1 For the parameters prefixed by an asterisk (*), setting becomes effective when the power is turned off once and back on after setting the parameter data.
(h) Status display
Device | Item | Symbol | |
name | |||
|
| ||
ST0 | Cumulative feedback pulses | ― | |
ST1 | Servo motor speed | ― | |
|
|
| |
ST2 | Droop pulses | ― | |
|
|
| |
ST3 | Cumulative command pulses | ― | |
ST4 | Command pulse frequency | ― | |
|
|
| |
ST5 | Analog speed command voltage/limit voltage | ― | |
|
|
| |
ST6 | Analog torque command voltage/limit voltage | ― | |
ST7 | Regenerative load ratio | ― | |
|
|
| |
ST8 | Effective load ratio | ― | |
|
|
| |
ST9 | Peak load ratio | ― | |
ST10 | Instantaneous torque | ― | |
|
|
| |
ST11 | Within | ― | |
|
|
| |
ST12 | ABS counter | ― | |
ST13 | Load inertia moment ratio | ― | |
|
|
| |
ST14 | Bus voltage | ― |
(i) Alarm
Device name | Item | Symbol | |
AL0 | Current alarm number | ― | |
AL1 | Detailed data of current alarms | ― | |
|
|
| |
AL11 | Servo status when alarm occurs cumulative | ― | |
feedback pulses | |||
|
| ||
|
|
| |
AL12 | Servo status when alarm occurs | ― | |
servo monitor speed | |||
|
| ||
|
|
| |
AL13 | Servo status when alarm occurs droop pulses | ― | |
|
|
| |
AL14 | Servo status when alarm occurs cumulative | ― | |
command pulses | |||
|
| ||
|
|
| |
AL15 | Servo status when alarm occurs command | ― | |
pulse frequency | |||
|
| ||
|
|
| |
| Servo status when alarm occurs analog |
| |
AL16 | speed command voltage | ― | |
| /limit voltage |
| |
|
|
| |
| Servo status when alarm occurs |
| |
AL17 | analog torque command voltage | ― | |
| /limit voltage |
| |
|
|
| |
AL18 | Servo status when alarm occurs | ― | |
regenerative load ratio | |||
|
| ||
|
|
| |
AL19 | Servo status when alarm occurs effective | ― | |
load ratio | |||
|
| ||
|
|
| |
AL20 | Servo status when alarm occurs peak load | ― | |
ratio | |||
|
| ||
|
|
| |
AL21 | Servo status when alarm occurs | ― | |
instantaneous torque | |||
|
| ||
|
|
| |
AL22 | Servo status when alarm occurs within one- | ― | |
revolution position | |||
|
| ||
|
|
| |
AL23 | Load inertia moment ratio ABS counter | ― | |
|
|
| |
AL24 | Servo status when alarm occurs | ― | |
load inertia moment ratio | |||
|
| ||
|
|
| |
AL25 | Servo status when alarm occurs bus voltage | ― | |
|
|
| |
AL200 | Alarm number from alarm history | ― | |
most recent alarm | |||
|
| ||
|
|
| |
AL201 | Alarm number from alarm history | ― | |
first alarm in past | |||
|
| ||
|
|
| |
AL202 | Alarm number from alarm history | ― | |
second alarm in past | |||
|
| ||
|
|
| |
AL203 | Alarm number from alarm history | ― | |
third alarm in past | |||
|
| ||
|
|
| |
AL204 | Alarm number from alarm history | ― | |
fourth alarm in past | |||
|
| ||
|
|
| |
AL205 | Alarm number from alarm history | ― | |
fifth alarm in past | |||
|
| ||
|
|
| |
AL210 | Alarm occurrence time in alarm history | ― | |
most recent alarm | |||
|
| ||
|
|
| |
AL211 | Alarm occurrence time in alarm history | ― | |
first alarm in past | |||
|
| ||
|
|
| |
AL212 | Alarm occurrence time in alarm history | ― | |
second alarm in past | |||
|
| ||
|
|
| |
AL213 | Alarm occurrence time in alarm history | ― | |
third alarm in past | |||
|
| ||
|
|
| |
AL214 | Alarm occurrence time in alarm history | ― | |
fourth alarm in past | |||
|
| ||
|
|
| |
AL215 | Alarm occurrence time in alarm history | ― | |
fifth alarm in past | |||
|
| ||
|
|
| |
AL230 | Detailed alarm from alarm history | ― | |
most recent alarm | |||
|
| ||
|
|
| |
AL231 | Detailed alarm from alarm history | ― | |
first alarm in past | |||
|
| ||
|
|
| |
AL232 | Detailed alarm from alarm history | ― | |
second alarm in past | |||
|
| ||
|
|
| |
AL233 | Detailed alarm from alarm history | ― | |
third alarm in past | |||
|
| ||
|
|
| |
AL234 | Detailed alarm from alarm history | ― | |
fourth alarm in past | |||
|
| ||
|
|
| |
AL235 | Detailed alarm from alarm history | ― | |
fifth alarm in past | |||
|
| ||
|
|
|
9
TO CONNECTIONPLC MELSECNET/H(PLCNETWORK)
10
MELSECNET/10 CONNECTION (PLC TO PLC NETWORK)
11
12
13
14
15
CONNECTION
INVERTER
16
CONNECTION
SERVO AMPLIFIER
16. SERVO AMPLIFIER CONNECTION | 16 - 33 |
16.6 Device Range that Can Be Set |
|