This section describes the settings of the GOT and
POINT
Connecting to
For details of
QnUCPU User's Manual (Communication via
System configuration
■ [Controller Setting] and [Ethernet] of GT
<GOT> |
|
(The settings other than the | |
following are set to the default) | |
Network No. | : 1 |
PLC No. | : 1 |
IP address | : 192.168.0.18 |
Port No. | : 5001 |
Communication : UDP(fixed) | |
format |
|
<Connecting to
1 Ethernet port CPU>
(The settings other than the following are set to the default)
Network No. | : 1 (virtual) *1 |
PLC No. | : 2 (virtual) *1 |
IP address | : 192.168.0.1 |
Port No. | : 5006(fixed) |
Communication : UDP(fixed) format
<Connecting to
2 (The settings other than the following are set to the default)
Network No. | : 1 (virtual) *1 |
PLC No. | : 3 (virtual) *1 |
IP address | : 192.168.0.2 |
Port No. | : 5006(fixed) |
Communication : UDP(fixed) format
■ [Q parameter setting] or [L parameter setting] for GX Developer
*1 These setting items do not exist at the PLC side. However, the virtual values must be set on the GOT side.
[Controller Setting] and [Ethernet] of GT Designer3
[Q parameter setting] or [L parameter setting] for GX Developer
(1)
Example: [Q parameter setting] screen
|
| Setting | |
Item | Set value | necessity at | |
GOT | |||
|
| ||
|
| connection | |
IP address | 192.168.0.1 |
| |
|
|
| |
Subnet mask pattern | - |
| |
|
|
| |
Default router IP address | - |
| |
|
|
| |
Communication data code |
|
| |
|
|
| |
Enable online change |
|
| |
(FTP, MC protocol) |
|
| |
|
|
| |
Disable direct connection | (Use default value) |
| |
to MELSOFT |
|
| |
|
|
| |
Do not respond to search |
|
| |
for CPU |
|
| |
port) on network |
|
| |
|
|
| |
Open settings | Refer to (2). |
|
FTP settings
(Use default value)
Time settings
: Necessary : As necessary : Not necessary
8 - 22 | 8. ETHERNET CONNECTION |
| 8.4 PLC Side Setting |