(b)Monitoring PLC CPU devices of other stations Set the device name and device No.
2. DEVICE RANGE THAT CAN BE SET
(3)Setting NW No. and station number
(a)When monitoring devices RX, RY, RWw and RWr that are allocated to the master station by
NW No.: 0, PLC station number: Local
(b)When monitoring PLC CPU devices of another station NW No. 0, PLC station number: Other (Station number: n)
(n: Station number of another station to be monitored (0: Master station,
POINT
For monitoring devices RX, RY, RWw and RWr that are allocated by
Otherwise, the display speed will be reduced.
When using
(1)Access range
GT16, GT15 and GT14 can monitor the master station and local stations. GT10 and GT11 can monitor the master station only.
(2)Setting NW No. and station number
(a)When monitoring master station
NW No.: 0, PLC station number: Host/other (station number: 0)
(b)When monitoring local station
NW No.: 0, PLC station number: Other (station number: 1 to 64)
(3)Setting device name and device number Set the device name and device No.
1
PREPARATORYFORPROCEDURESMONITORING 2
RANGESETBE
DEVICE CANTHAT 3
RANGEACCESS MONITORINGFOR 4
MONITORTOREDUNTANTSYSTEM HOW 5
CONNECTIONBUS 6
DIRECTTOCONNECTIONCPU 7
LINKCOMPUTER CONNECTION 8
ETHERNETCONNECTION
3. ACCESS RANGE FOR MONITORING | 3 - 15 |