Parameter setting (when connecting to
(1)[Network parameter] of GX Developer
(a)Network parameter
|
| Setting | |
Item | Set value | necessity | |
at GOT | |||
|
| ||
|
| connection | |
No. of boards in module | 1 |
| |
|
|
| |
Start I/O No. | 0000H |
| |
|
|
| |
Operation setting | (Use default value) |
| |
|
|
| |
Type | Master station (fixed) |
| |
|
|
| |
Mode | Remote net |
| |
(Ver.1 mode) |
| ||
|
| ||
|
|
| |
All connect count | 1 |
| |
|
|
| |
Remote input (RX) | X400 |
| |
|
|
| |
Remote output (RY) | Y400 |
| |
|
|
| |
Remote register (RWr) | D300 |
| |
|
|
| |
Remote register (RWw) | D200 |
| |
|
|
| |
Special relay (SB) | SB0 |
| |
|
|
| |
Special register (SW) | SW0 |
| |
|
|
| |
Retry count |
|
| |
|
|
| |
Automatic reconnection |
|
| |
station count |
|
| |
|
|
| |
Stand by master station No. | (Use default value) |
| |
|
| ||
PLC down select |
|
| |
|
|
| |
Scan mode setting |
|
| |
|
|
| |
Delay information setting |
|
| |
|
|
| |
Station information setting | Refer to (b). |
| |
|
|
| |
Remote device station initial |
|
| |
settings | (Use default value) |
| |
|
| ||
Interrupt setting |
|
| |
|
|
|
: Necessary : As necessary : Not necessary
(b) Station information setting
|
|
|
| Setting |
Item*1 |
|
| Set value | necessity |
|
| at GOT | ||
|
|
|
| |
|
|
|
| connection |
Station type |
| Intelligent device |
| |
| station (fixed) |
| ||
|
|
| ||
|
|
|
| |
Exclusive station count*2 |
| Exclusive station 1 |
| |
Reserve/invalid station |
|
| No setting |
|
select |
|
|
| |
|
|
|
| |
|
|
|
|
|
Intelligent buffer select |
| (Use default value) |
| |
(word) |
|
| ||
|
|
|
| |
|
|
|
|
|
| : Necessary | : As necessary | : Not necessary |
*1 When the [Mode] of the
*2 Set the same number of occupied stations as that on the GOT.
POINT
When changing the network parameter
After writing the network parameter to the PLC CPU, operate the PLC CPU ether turning OFF and then ON or resetting.
13 - 14 | 13. |
| 13.4 PLC Side Setting |