(2)Connecting the GOT and PLC in computer link connection (when connecting to QJ71C24 (N))

1.

Click the Connection Destination view

 

[Connection Destination]

[(Connection target data

 

name)] in the Navigation window of GX Works2.

2.

The [Transfer Setup Connection1] is displayed.

3.

Set the [Transfer Setup Connection1]:

 

PC side I/F

: Serial USB

 

PLC side I/F

: GOT

 

Other Station Setting

: No Specification

4. Double-click [Serial USB] of the PC side I/F to display [PC side I/F Serial Setting].

5. Check-mark either of the following in [PC side I/F Serial Setting].

When connecting the GOT and PC with serial When connecting the GOT to PC via modem

Mark the [RS-232C] checkbox.

When connecting the GOT and PC with USB

Mark the [USB] checkbox.

6. Double-click [GOT] of the PLC side I/F to display [PLC side I/F Detailed Setting of GOT].

7. Check-mark [C24] in [PLC side I/F Detailed Setting of GOT].

8. The screen returns to [Transfer Setup Connection1]. Click [Connection Test] to check if GX Works2 has been connected to the QCPU (Q mode).

22 - 44

22. FA TRANSPARENT FUNCTION

 

22.6 Personal Computer Side Setting