Set [FX3U-ENET-ADP] or [Ethernet Module] for [PLC Type].

GOT(Ethernet) Transparent Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

OK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLC Type

 

 

 

 

 

 

 

 

 

 

 

Cancel

FX3U-ENET-ADP

 

 

 

 

 

 

 

 

 

 

FX3U-ENET-ADP

 

 

 

 

 

 

 

 

 

Ethernet Module

 

 

 

 

 

 

 

 

Module Side

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IP Address

 

0

0

0

0

 

IP Input Format

DEC.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8. By clicking [Set], the [GOT (Ethernet) transparent setting] is displayed.

Here, set the [FX3U-ENET-ADP] or [Ethernet Module], which is connected via a GOT.

9.

10.Specify the IP address for [IP address] same as the IP address assigned to the [FX3U-ENET-ADP] or [Ethernet Module].

11.The screen returns to [Transfer Setup]. Click [Connection Test] to check if GX Developer has been connected to the FXCPU.

(4)Connecting the GOT and Ethernet adapter (NZ2GF- ETB) in Ethernet connection, and connecting it to a PLC in the CC-Link IE Field Network.

This section describes the settings of the GX Works2 in the following case of system configuration.

POINT

Version of GX Works2

GX Works2 Version 1.34L or later is required to execute the FA transparent function with using Ethernet adapter (NZ2GF-ETB).

<GOT>

(Use default value for settings other than the following.)

Network No.

:3

PC No.

:1

IP address

:192.168.3.18

Port No.

:5001

Communication :UDP (fixed) format

Ethernet

<Ethernet adapter module>

(Use default value for settings other than the following.)

Ethernet setting

:192.168.3.30

IP address

CC-Link IE Field Network setting

Network No.

:1

Station No.

:1

CC-Link IE Field Network

HUB

<CC-Link IE Field Network Master/Local module> (Use default value for settings other than the following.)

Network Type

 

: CC IE Field (Master station)

Network No.

: 1

PC No.

: 0

Total Stations

: 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<CC-Link IE Field Network Master/Local module> (Use default value for settings other than the following.)

Network Type

: CC IE Field (Local station)

Network No.

: 1

PC No.

: 2

17

ROBOT CONTROLLER CONNECTION

18

CNC CONNECTION

19

CONNECTION

GOT MULTI-DROP

20

MULTIPLE-GT14, GT12, GT11, GT10 CONNECTION FUNCTION

21

FUNCTION

MULTI-CHANNEL

22

FUNCTION

FA TRANSPARENT

22. FA TRANSPARENT FUNCTION

22 - 47

22.6 Personal Computer Side Setting