HP Manager Software manual Set radio-profile auto-tune channel-interval

Models: Manager Software

1 616
Download 616 pages 38.63 Kb
Page 332
Image 332

332CHAPTER 9: MANAGED ACCESS POINT COMMANDS

„holddown — Minimum number of seconds a radio must remain on its current channel setting before RF Auto-Tuning is allowed to change the channel. You can specify from 0 to 65535 seconds.

Defaults — The default RF Auto-Tuning channel holddown is 900 seconds.

Access — Enabled.

History —Introduced in MSS Version 3.0.

Usage — The channel holddown applies even if RF anomalies occur that normally cause an immediate channel change.

Examples — The following command changes the channel holddown for radios in radio profile rp2 to 600 seconds:

WX4400# set radio-profile rp2 auto-tunechannel-holddown 600 success: change accepted.

See Also

„set radio-profileauto-tunechannel-configon page 330

„set radio-profileauto-tunechannel-intervalon page 332

set radio-profile auto-tune channel-interval

Sets the interval at which RF Auto-Tuning decides whether to change the channels on radios in a radio profile. At the end of each interval, MSS processes the results of the RF scans performed during the previous interval, and changes radio channels if needed.

Syntax set radio-profile name auto-tune channel-interval

seconds

„name — Radio profile name.

„seconds — Number of seconds RF Auto-Tuning waits before changing radio channels to adjust to RF changes, if needed. You can specify from 0 to 65535 seconds.

Defaults — The default channel interval is 3600 seconds (one hour).

Access — Enabled.

History —Introduced in MSS Version 3.0.

Page 332
Image 332
HP Manager Software Set radio-profile auto-tune channel-interval, Syntax set radio-profile name auto-tune channel-interval