SNMPv2c with Traps

To configure a notification target for traps from SNMPv2c, use the following command:

Syntax set snmp notify target target-num

ip-addr[:udp-port-number]

v2c community-string trap

[profile profile-name]

„target-num— ID for the target. This ID is local to the WX switch and does not need to correspond to a value on the target itself. You can specify a number from 1 to 10.

„ip-addr[:udp-port-number]— IP address of the server. You also can specify the UDP port number to send notifications to.

„community-string— Community string.

„profile profile-nameNotification profile this SNMP user will use to specify the notification types to send or drop.

SNMPv1 with Traps

To configure a notification target for traps from SNMPv1, use the following command:

Syntax set snmp notify target target-num

ip-addr[:udp-port-number] v1 community-string [profile profile-name]

„target-num— ID for the target. This ID is local to the WX switch and does not need to correspond to a value on the target itself. You can specify a number from 1 to 10.

„ip-addr[:udp-port-number]— IP address of the server. You also can specify the UDP port number to send notifications to.

„community-string— Community string.

„profile profile-nameNotification profile this SNMP user will use to specify the notification types to send or drop.