HP Manager Software manual „ trace Sets log parameters for trace files

Models: Manager Software

1 616
Download 616 pages 38.63 Kb
Page 587
Image 587

set log 587

„sessions — Sets the default log values for Telnet sessions. You can set defaults for the following log parameters:

„Severity

„Logging state (enabled or disabled)

To override the session defaults for an individual session, type the set log command from within the session and use the current option.

„trace — Sets log parameters for trace files.

„severity severity-level— Logs events at a severity level greater than or equal to the level specified. Specify one of the following:

„emergency — The WX switch is unusable.

„alert — Action must be taken immediately.

„critical — You must resolve the critical conditions. If the conditions are not resolved, the WX can reboot or shut down.

„error — The WX is missing data or is unable to form a connection.

„warning — A possible problem exists.

„notice — Events that potentially can cause system problems have occurred. These are logged for diagnostic purposes. No action is required.

„info — Informational messages only. No problem exists.

„debug — Output from debugging.

„local-facilityfacility-levelFor messages sent to a syslog server, maps all messages of the severity you specify to one of the standard local log facilities defined in RFC 3164. You can specify one of the following values:

„0 — maps all messages to local0.

„1 — maps all messages to local1.

„2 — maps all messages to local2.

„3 — maps all messages to local3.

„4 — maps all messages to local4.

„5 — maps all messages to local5.

„6 — maps all messages to local6.

„7 — maps all messages to local7.

Page 587
Image 587
HP Manager Software manual „ trace Sets log parameters for trace files