HP Manager Software manual Save trace, Set trace, Authentication

Models: Manager Software

1 616
Download 616 pages 38.63 Kb
Page 564
Image 564

564CHAPTER 19: TRACE COMMANDS

save trace

Saves the accumulated trace data for enabled traces to a file in the WX

 

switch’s nonvolatile storage.

 

Syntax save trace filename

 

„ filename — Name for the trace file. To save the file in a subdirectory,

 

specify the subdirectory name, then a slash. For example: traces/trace1

 

Defaults — None.

 

Access — Enabled.

 

History —Introduced in MSS Version 3.0.

 

Examples — To save trace data into the file trace1 in the subdirectory

 

traces, type the following command:

 

WX4400# save trace traces/trace1

 

 

set trace

Traces authentication information.

authentication

Syntax set trace authentication [mac-addr mac-address]

 

 

[port port-num] [user username] [level level]

 

„ mac-addrmac-addressTraces a MAC address. Specify a MAC

 

address, using colons to separate the octets (for example,

 

00:11:22:aa:bb:cc).

 

„ port port-numTraces on a WX port number.

 

„ user username Traces a user. Specify a username of up to

 

32 alphanumeric characters with no spaces.

 

„ level level Determines the quantity of information included in

 

the output. You can set the level with an integer from 1 to 10, where

 

level 10 provides the most information. Levels 1 through 5 provide

 

user-readable information. If you do not specify a level, level 5 is the

 

default.

 

Defaults — The default trace level is 5.

 

Access — Enabled.

 

History —Introduced in MSS Version 3.0.

Page 564
Image 564
HP Manager Software manual Save trace, Set trace, Authentication