Source (Internal)
Continuous
Sets the active trigger type to Continuous. If Continuous is already selected as the active trigger type, pressing this
key allows access to the continuous trigger type setup menu. In Continuous trigger mode, the waveform repeats
continuously.
Free Run
Selects Free Run as the trigger response for the continuous trigger type. Free Run sets the waveform generator to
play a waveform sequence or segment continuously, without waiting for a trigger. In this mode, the waveform
generator does not respond to triggers.
Trigger + Run
Sets Trigger and Run as the trigger response for the continuous trigger type. Trigger and Run sets the waveform
generator to play a waveform sequence or segment continuously when the first trigger is received, and to ignore
any subsequent triggers.
Remote Command: :SOURce:RADio:ARB:TRIGger:TYPE CONTinuous | SINGle |
SADVance GATE
:SOURce:RADio:ARB:TRIGger:TYPE?
Example: SOUR:RAD:ARB:TRIG:TYPE CONT
SOUR:RAD:ARB:TRIG:TYPE?
Notes: Gated trigger type will be implemented at a later release
Preset: CONTinuous
Range: Continuous | Single | Seg Adv | Gated
Initial S/W Revision: A.05.00
Key Path: Source, Modulation Setup, ARB, Trigger Type
Remote Command: :SOURce:RADio:ARB:TRIGger:TYPE:CONTinuous[:TYPE]
FREE|TRIGger|RESet
:SOURce:RADio:ARB:TRIGger:TYPE:CONTinuous[:TYPE]?
Example: SOUR:RAD:ARB:TRIG:TYPE:CONT FREE
Preset: FREE
Range: Free Run | Trigger + Run | Reset + Run
Initial S/W Revision: A.05.00
Key Path: Source, Modulation Setup, ARB, Trigger Type, Continuous
Example: SOUR:RAD:ARB:TRIG:TYPE:CONT FREE
Initial S/W Revision: A.05.00
Key Path: Source, Modulation Setup, ARB, Trigger Type, Continuous