699
Code Domain
SPAN X Scale
SPAN X Scale

Accesses a menu of functions that enable you to set the desired horizontal scale parameters.

Numbers and default numbers are independent for each window.

Metrics window and I/Q Symbol Polar Vector and Demod Bits window do not have this menu (Blank

menu).

Start Code Number

Sets the start value of the code range for the code domain power graph (CDP) and CDE graph

Key Path Front-panel key
Mode cdma2000
Remote Command :DISPlay:CDPower:CDOMain:SPAN:STARt <integer>
:DISPlay:CDPower:CDOMain:SPAN:STARt?
Example DISP:CDP:CDOM:SPAN:STAR 5
DISP:CDP:CDOM:SPAN:STAR?
Restriction and Notes In MS mode, there are 32 codes in all. This key is grayed out.
Dependencies/Couplings Start Code Number and Stop Code Number are coupled to each other,
according to:
(A) Stop Code Number > Start Code Number
and
(B) Stop Code Number – Start Code Number >= 63
When changing the start code number, if it does not satisfy the above
conditions, the stop code number is changed to satisfy (A) and (C).
(C) Stop Code Number – Start Code Number = 63;
Preset 0
State Saved Saved in instrument state.
Min 0
Max 64
Key Path Span X Scale