574
Spectrum Emission Mask Measurement
View/Display
Trace Window
Results Window
Abs Peak Pwr & Freq (Spectrum Pk Ref)
This view consists of the following two windows:
“Trace Window” on page 574
“Results Window ” on page 574
Corresponding Trace yellow - Combined trace from carrier and each offset
Name Corresponding Results
Total Pwr n=1 2nd element
Absolute power at the reference area.
Channel Integration Bandwidth
PSD Ref n=5 1st element
Power spectral density reference at the reference area
Start (Hz) Start frequency for offset
Stop (Hz) Stop frequency for offset
Meas BW (Hz) Measurement bandwidth for offset
Lower (dBm/Hz) Absolute power spectrum density of the negative offset
Lower lim (dB) Minimum margin from limit line which is decided by Fail Mask
setting on the negative offset
Lower Freq (Hz) Frequency on minimum margin point of the negative offset
Upper (dBm/Hz) Absolute power spectrum density of the positive offset
Upper lim (dB) Minimum margin from limit line which is decided by Fail Mask
setting on the positive offset
Upper Freq (Hz) Frequency on minimum margin point of the positive offset