651
Code Domain
not specified
or n = 1 The average power of active code (absolute or relative to Total Power) over one PCG specified
by Meas Offset.
If no active codes are detected, the value returned is –999.0.
In MS mode, the value returned is –999.0.
12. Maximum inactive traffic power: (floating) [dBc or dBm]
The maximum power of inactive code (absolute or relative to Total Power) over one PCG
specified by Meas Offset.
In MS mode, the value returned is –999.0.
13. Average inactive traffic power: (floating) [dBc or dBm]
The average power of inactive code (absolute or relative to Total Power) over one PCG
specified by Meas Offset.
In MS mode, the value returned is –999.0.
14. Number of active channels: (integer) [no unit]
The total number of active codes.
In MS mode, the value returned is –999.
15. I channel average active power: (floating) [dBc or dBm]
The average power of the active I channels (absolute or relative to Total Power).
If no active codes are detected, the value returned is –999.0.
In BTS mode, the value returned is –999.0.
16. I channel maximum inactive power: (floating) [dBc or dBm]
The maximum power of the inactive I channels (absolute or relative to Total Power).
In BTS mode, the value returned is –999.0
17. Q channel average active power: (floating) [dBc or dBm]
The average power of the active Q channels (absolute or relative to Total Power).
If no active codes are detected, the value returned is –999.0.
In BTS mode, the value returned is –999.0.
18. Q channel maximum inactive: (floating) [dBc or dBm]
The maximum power of the inactive Q channels (absolute or relative to Total Power).
In BTS mode, the value returned is –999.0
19. Time between trigger to PN offset: (floating) [Éþs]
The time from the trigger point to the PN offset.
In the MS mode, the valued returned is –999.0.