521
Spectrum Emission Mask Measurement
Meas Setup
Offset Side
Specifies which offset side to measure.
You can turn off (not use) specific offsets with [:SENSe]:SEMask:OFFSet[n]:LIST:STATe.
•BOTH - both of the negative (lower) and positive (upper) sidebands
•NEGative - negative (lower) sideband only
•POSitive - positive (upper) sideband only
Res BW
Specifies which Resolution BW filter to use when measuring the currently selected offset.
Offset Res BW Mode allows the instrument to determine the optimum Resolution BW filter to use when
measuring the currently selected offset.. When changing the Meas BW parameter, if the Res BW needs
to be changed to adhere to the rule
(N x Res BW) <= (Stop freq of the offset - Start freq of the offset),
Modified at S/W Revision: A.02.00, A.03.00, A.10.00, A.11.00
Key Path: Meas Setup, Offset/Limits
Mode: WCDMA, C2K, WIMAX OFDMA, TD-SCDMA, 1xEVDO, LTE, LTETDD,
WLAN
Remote Command: [:SENSe]:SEMask:OFFSet[1]|2:LIST:SIDE
BOTH|NEGative|POSitive, …
[:SENSe]:SEMask:OFFSet[1]|2:LIST:SIDE?
Example: SEM:OFFS:LIST:SIDE BOTH, NEG, NEG, POS, POS, POS
SEM:OFFS:LIST:SIDE?
Notes: Comma separated list of values.
OFFSet1 is for BTS, 2 for MS. Default is BTS.
You must be in the mode that includes SEM measurement to use this
command. Use :INSTrument:SELect to set the mode.
Preset: Modes (except WLAN): BOTH, BOTH, BOTH, BOTH, BOTH, BOTH
WLAN: BOTH, BOTH, BOTH, BOTH, BOTH, BOTH, BOTH, BOTH,
BOTH, BOTH, BOTH, BOTH
State Saved: Saved in instrument state.
Range: Neg|Both|Pos
Initial S/W Revision: Prior to A.02.00
Modified at S/W Revision: A.02.00, A.03.00, A.10.00, A.11.00