Sweep/Control
Sweep Time RulesAllows the choice of three distinct sets of sweep time rules. These are the rules that are used to set the sweep time when Sweep Time is in Auto mode. Note that these rules only apply when in the Swept
Sweep Type (either manually or automatically chosen) and not when in FFT sweeps.
See “More Information” on page 1271.
Key Path: Sweep/Control, Sweep Setup
Remote Command: [:SENSe]:SWEep:TIME:AUTO:RULes
NORMal|ACCuracy|SRESponse
[:SENSe]:SWEep:TIME:AUTO:RULes?
Example: SWE:TIME:AUTO:RUL ACC
Dependencies: In Zero Span, this key is irrelevant and cannot be accessed (because the whole
Sweep Setup menu is grayed out in Zero Span), however its settings can be
changed remotely with no error indication.
Grayed out in FFT sweeps. Pressing the key while the instrument is in FFT
sweep generates an advisory message. The SCPI is acted upon if sent, but has
no effect other than to change the readout on the key, as long as the analyzer is
in an FFT sweep.
Couplings: Set to Auto on Auto Couple
Preset: AUTO
State Saved: Saved in instrument state
Backwards Compatibility SCPI: :SWEep:TIME:AUTO:MODE SRESponse
This legacy command is aliased to :SWEep:TIME:AUTO:RULes
SRESponse
Backwards Compatibility SCPI: :SWEep:TIME:AUTO:MODE SANalyzer
This legacy command is aliased to :SWEep:TIME:AUTO:RULes NORMal
Backwards Compatibility SCPI: :SWEep:TIME:AUTO:MODE?
This legacy query is aliased to :SWEep:TIME:RULes?, so it will match for
SRESponse but not for SANalyzer
Backwards Compatibility Notes: The old Auto Sweep Time command was the same
[:SENSe]:SWEep:TIME:AUTO:RULes NORMal|ACCuracy
so it still works although it now has a third parameter (SRESponse).
The old Sweep Coupling command was
[:SENSe]:SWEep:TIME:AUTO:MODE SRESponse|SANalyzer and it is
aliased as below:
Initial S/W Revision: Prior to A.02.00