763
Modulation Accuracy (Composite Rho)
SPAN X Scale
I/Q Error View - Phase Error WindowSets the horizontal scale by changing a chip value per division in the phase error window.
Remote Command :DISPlay:RHO:VIEW2:WINDow2:TRACe:X[:SCALe]:PDIVisi
on <real>
:DISPlay:RHO:VIEW2:WINDow2:TRACe:X[:SCALe]:PDIVisi
on?
Example DISP:RHO:VIEW2:WIND2:TRAC:X:PDIV 100.0
DISP:RHO:VIEW2:WIND2:TRAC:X:PDIV?
Restriction and Notes If Auto Scaling is set to On, this value is automatically determined by
the measurement result. When you set this value manually, Auto
Scaling is automatically set to Off.
Dependencies/Couplings See Restriction and Notes
Remote Command Notes WINDow2: Mag Error window on I/Q Error view
Preset 153.6
State Saved Saved in instrument state.
Min 1.0
Max 500000.0
Key Path Span X Scale
Mode cdma2000
Remote Command :DISPlay:RHO:VIEW2:WINDow3:TRACe:X[:SCALe]:PDIVisi
on <real>
:DISPlay:RHO:VIEW2:WINDow3:TRACe:X[:SCALe]:PDIVisi
on?
Example DISP:RHO:VIEW2:WIND3:TRAC:X:PDIV 100.0
DISP:RHO:VIEW2:WIND3:TRAC:X:PDIV?
Restriction and Notes If Auto Scaling is set to On, this value is automatically determined by
the measurement result. When you set this value manually, Auto
Scaling is automatically set to Off.
Dependencies/Couplings See Restriction and Notes
Remote Command Notes WINDow3: Phase Error window on I/Q Error view
Preset 153.6
State Saved Saved in instrument state.
Min 1.0
Max 500000.0