690
Code Domain
Meas Setup
Long Code Mask (MS only)Capture Interval

Sets the data capture length in PCG (1PCG = 1.25 ms) that is used in the acquisition.

Spectrum Inversion

Toggles the spectrum function between Normal and Invert.

Invert: This function conjugates the spectrum, which is equivalent to taking the negative of the

Mode cdma2000
Remote Command [:SENSe]:CDPower:SYNC:LCMask <integer>
[:SENSe]:CDPower:SYNC:LCMask?
Example CDP:SYNC:LCM 0
CDP:SYNC:LCM?
Restriction and Notes Set the long code mask for MS measurement.
Dependencies/Couplings Only available when [:SENSe]:RADio:DEVice is MS.
Remote Command Notes You must be in cdma2000 to use this command
Preset 0
State Saved Saved in instrument state.
Min 0
Max 4,398,046,511,103 (3FFFFFFFFFF)
Key Path Meas Setup
Mode cdma2000
Remote Command [:SENSe]:CDPower:CAPTure:TIME <integer>
[:SENSe]:CDPower:CAPTure:TIME?
Example CDP:CAPT:TIME 32
CDP:CAPT:TIME?
Remote Command Notes You must be in cdma2000 to use this command
Preset 5
State Saved Saved in instrument state.
Min 2
Max 32
Key Path Meas Setup