663
Code Domain
AMPTD Y Scale
CDP view.CDP Graph & CDE Graph View CDP Window Y Scale/DivSets the vertical display sensitivity measurement result for Code Domain Power and Code Domain Error graph views in the CDP window.
Mode cdma2000
Remote Command :DISPlay:CDPower:VIEW[1]:WINDow[1]:TRACe:Y[:SCALe]
:PDIVision <real>
:DISPlay:CDPower:VIEW[1]:WINDow[1]:TRACe:Y[:SCALe]
:PDIVision?
Example DISP:CDP:VIEW:WIND:TRAC:Y:PDIV 5.0
DISP:CDP:VIEW:WIND:TRAC:Y:PDIV?
Restriction and Notes Target window to control depends on the SubOpCode.
Remote Command Notes Target window to control depends on the SubOpCode.
Preset 10.00
State Saved Saved in instrument state.
Min 0.10
Max 20.00
Key Path AMPTD Y Scale
Mode cdma2000
Remote Command :DISPlay:CDPower:VIEW2:WINDow[1]:TRACe:Y[:SCALe]:P
DIVision <real>
:DISPlay:CDPower:VIEW2:WINDow[1]:TRACe:Y[:SCALe]:P
DIVision?
Example DISP:CDP:VIEW2:WIND:TRAC:Y:PDIV 5.0
DISP:CDP:VIEW2:WIND:TRAC:Y:PDIV?
Restriction and Notes Target window to control depends on the SubOpCode.
Remote Command Notes Target window to control depends on the SubOpCode.
Preset 10.00
State Saved Saved in instrument state.
Min 0.10
Max 20.00
Key Path AMPTD Y Scale