571
Spectrum Emission Mask Measurement
View/Display
Trace Window
Results Window
Corresponding Trace yellow - Combined trace from carrier and each offset
Name Corresponding Results
Total Pwr Ref n=1 2nd element
Absolute power at the reference area.
Channel Integration Bandwidth
Start (Hz) Start frequency for offset
Stop (Hz) Stop frequency for offset
Meas BW (Hz) Measurement bandwidth for offset
Lower Peak (dBm) Absolute peak power on minimum margin point of the negative
offset
Lower lim (dB) Minimum margin from limit line which is decided by Fail Mask
setting on the negative offset
Lower Freq (Hz) Frequency on minimum margin point of the negative offset
Upper Peak (dBm) Absolute peak power on minimum margin point of the positive
offset
Upper lim (dB) Minimum margin from limit line which is decided by Fail Mask
setting on the positive offset
Upper Freq (Hz) Frequency on minimum margin point of the positive offset