754
Modulation Accuracy (Composite Rho)
Meas Setup
Filter Alpha
Specifies the alpha value of the complimentary filter.
Example CALC:RHO:ASET:THR –20.0
CALC:RHO:ASET:THR?
CALC:RHO:ASET:THR:AUTO ON
CALC:RHO:ASET:THR:AUTO?
Restriction and Notes This command is effective when [:SENSe]:RHO:SBOundary[:BTS] is set to
AUTO. (For MS, this command is always effective.)
Remote Command Notes Turn the automatic mode On or Off, for the active channel identification
function.
OFF – The active channel identification for each code channel is determined
by a value set by CALCulate:RHO:ASET:THReshold.
ON – The active channels are determined automatically by the internal
algorithm.
Preset 0.0
ON
State Saved Saved in instrument state.
Min –100.0
Max 0.0
Key Path Meas Setup, Advanced
Mode cdma2000
Remote Command [:SENSe]:RHO:ALPHa <real>
[:SENSe]:RHO:ALPHa?
Example RHO:ALPH 0.15
RHO:ALPH?
Preset 0.15
State Saved Saved in instrument state.
Min 0.05
Max 0.20
Key Path Meas Setup, Advanced