Command Reference Guide VLAN Interface Config Command Set
61200510L1-35E Copyright © 2005 ADTRAN 1213
snmp trap link-status
Use the snmp trap link-status command to control the Simple Network Management Protocol (SNMP)
variable ifLinkUpDownTrapEnable (RFC 2863) to enable (or disable) the interface to send SNMP traps
when there is an interface status change. Use the no form of this command to disable this trap.
Syntax Description
No subcommands.
Default Values
By default, the ifLinkUpDownT rapEnable OID is set to enabled for all interfaces except virtual Frame Relay
interfaces.
Applicable Platforms
This command applies to the NetVanta 300, 1000, 1000R, and 2000 Series units.
Command History
Release 1.1 Command was introduced.
Release 3.1 Command was extended to the SHDSL interface .
Release 5.1 Command was expanded to include Gigabit Ethernet, port channel, VLAN, E1,
and G.703 interfaces.
Release 6.1 Command was expanded to include VLAN interfaces.
Functional Notes
The snmp trap link-st atus command is used to control the RFC 2863 ifLinkUpDownT rapEnable OID (OID
number 1.3.6.1.2.1.31.1.1.1.14.0).
Usage Examples
The following example disables the link-status trap on the VLAN interface:
(config)#interface vlan 1
(config-interface-vlan 1)#no snmp trap link-status