Command Reference Guide Global Configuration Mode Command Set
61200510L1-35E Copyright © 2005 ADTRAN 528

thresholds [BES | CSS | DM | ES | LCV | LES | PCV | SEFS | SES | UAS]

[15Min | 24Hr] <threshold count>

Use the thresholds command to specify DS1 performance counter thresholds. Use the no form of this

command to return to default settings.

Syntax Description
BES Specifies the bursty errored seconds threshold.
CSS Specifies the controlled slip seconds threshold.
DM Specifies the degraded minutes threshold.
ES Specifies the errored seconds threshold.
LCV Specifies the line code violations th reshold.
LES Specifies the line errored seconds threshold.
PCV Specifies the path coding violations threshold.
SEFS Specifies the severely errored framing se conds threshold.
SES Specifies the severely errored seconds threshold.
UAS Specifies the unavailable seconds threshold.
15Min S pecifies tha t the threshold you are setting is for the counter’s 15 minute st atistics.
24Hr Specifies that the threshold you are setting is for the counter’s 24 hour statistics.
<threshold> Specifies the maximum occurrences allowed for this error type. Once a threshold
is exceeded, an event is sent to the console specifying the appropriate counter.
Additionally, if SNMP traps are enabled, the unit will send a trap with the same
information as the console event.
Default Values
The default values for this command are as follows:
thresholds BES 15Min 10
thresholds BES 24Hr 100
thresholds CSS 15Min 1
thresholds CSS 24Hr 4
thresholds DM 15Min 1
thresholds DM 24Hr 4
thresholds ES 15Min 65
thresholds ES 24Hr 648
thresholds LCV 15Min 13340
thresholds LCV 24Hr 133400
thresholds LES 15 Mi n 65
thresholds LES 24Hr 648
thresholds PCV 15Min 72
thresholds PCV 24Hr 691

Threshold settings are applied to ALL DS1s.