Command Reference Guide Enable Mode Command Set
61200510L1-35E Copyright © 2005 ADTRAN 190

show garp timer

Use the show garp timer command to see the current co nfigured Generic Attribute Registration Protocol
(GARP) application timer values.
Syntax Description
No subcommands.
Default Values
No default value necessary for this command.
Applicable Platforms
This command applies to the NetVanta 300, 1000, and 1000R Series units.
Command History
Release 8.1 Command was introduced.
Usage Examples
The following example displays the current configured GARP app lication timer values:
>enable
#show garp timer
Timer Timer Value (milliseconds)
-------- --------------------------
Join 200
Leave 600
LeaveAll 10000