Command Reference Guide DSX-1 Interface Configuration Command Set
61200510L1-35E Copyright © 2005 ADTRAN 589

line-length <value>

Use the line-length command to set the line build out (in feet or dB) for the DSX-1 interface. Use the no
form of this command to return to the default value.
Syntax Description
<value> Configures the line b uild out for the DSX-1 interface. Valid options include: -7.5 dB
or 0 to 655 feet. Use the -7.5 dB option for maximum attenuation.
Default Values
By default, the line build out is set to 0 feet.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, 4000, and 5000 and Total Access 900 Series units.
Command History
Release 1.1 Command was introduced.
Functional Notes
The line-length value represents the physical distance between DSX equipment (measured in cable
length). Based on this setting, the AOS device increases signal strength to compensate for the distance
the signal must travel. Valid distance ranges are listed below:
0 to 133 feet
134 to 265 feet
266 to 399 feet
400 to 533 feet
534 to 655 feet
Usage Examples
The following example configures the DSX-1 interface line-length for 300 feet:
(config)#interface t1 1/2
(config-t1 1/2)#line-length 300