Command Reference Guide Frame Relay Interface Config Command Set
61200510L1-35E Copyright © 2005 ADTRAN 849

frame-relay lmi-n391dte <polls>

Use the frame-relay lmi-n391dte command to set the N391 full status polling counter for the DTE
endpoint. Typical applications should leave the default value for this timer. Use the no form of this
command to return to the default value.
Syntax Description
<polls> Sets the counter value (valid range: 1 to 255).
Default Values
By default, the polling counter for the DTE endpoint is set to six polls.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, 4000, and 5000 and Total Access 900 Series units.
Command History
Release 1.1 Command was introduced.
Functional Notes
The N391 counter determines how many link integrity polls occur in between full status polls. The number
of link integrity polls between full status polls is n - 1, where n represent s the full st atus poll. n can be set to
any number be twe e n 1 an d 25 5 , but the default is used for most applications.
Usage Examples
The following example sets the N391 counter for three polls:
(config)#interface frame-relay 1
(config-fr 1)#frame-relay lmi-n391dte 3