Command Reference Guide SHDSL Interface Configuration Command Set
61200510L1-35E Copyright © 2005 ADTRAN 691

linerate <value>

Use the linerate command to define the line rate for the SHDSL interface (the value includes 8 kbps of
framing overhead). This command is functional on ly in CO operating mode (see the section
equipment-type [co | cpe] on page 688). The first two selections listed in the CLI (72 and 136 kbps) are not
supported by the SHDSL NIM (1200867L1).
Syntax Description
<value> Specifies the line rate in kbps. Range: 200 to 2312 kbp s in 64k increments.
Default Values
The default for this command is 2056 kbps.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, and 4000 Series units.
Command History
Release 3.1 Command was introduced.
Usage Examples
The following example changes the line rate of the SHDSL interface to 264 kbps:
(config)#interface shdsl 1/1
(config-shdsl 1/1)#linerate 264