Command Reference Guide Demand Interface Configuration Command Set
61200510L1-35E Copyright © 2005 ADTRAN 791

connect-order [last-successful | round-robin | sequential]

Use the connect-order command to specify the starting point in the connection sequence for each
sequence activation. The connection sequence is a circular list. Use the no form of this command to restore
the default values.
Syntax Description
last-successful Specifies the connect sequence be processed beginning with the last successful
entry or the first entry if there are no previous connections.
round-robin Specifies the connect sequence be processed beginning with the entry that
follows the last successful entry or the first entry if there are no previous
connections.
sequential Specifies the connect seque nce be processed from the beginning of the li st.
Default Values
By default, connect sequ e nc es ar e pr o ces se d seq u entia lly.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, 4000, and 5000 Series units.
Command History
Release 11.1 Command was introduced.
Usage Examples
The following example configures the connection sequence to begin with the last successful entry:
(config)#interface demand 1
(config-demand 1)#connect-order last -successful