Command Reference Guide Frame Relay Sub-Interface Config Command Set
61200510L1-35E Copyright © 2005 ADTRAN 881
dial-backup maximum-retry <attempts>
Use the dial-backup maximum-retry command to select the number of calls the router will make when
attempting to backup a link. Use the no form of this command to return to the default state. For more
detailed information on Frame Relay dial-backup functionality, refer to the Functional Notes and
Technology Re view sections of the command dial-backup call-mode [answer | answer-always | originate |
originate-answer | originate-answer-always] on page 876.
Syntax Description
<attempts> Selects the number of call retries that will be made after a link failure (valid range:
0 to 15).
Setting this value to 0 will allow unlimited retries during the time the network is
failed.
Default Values
By default, dial-backup maximum-retry is set to 0 attempts.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, 4000, and 5000 Series units.
Command History
Release 1.1 Command was introduced.
Usage Examples
The following example co nfigures the AOS to retry a dial- backup call four times be fore considering ba ckup
operation not available:
(config)#interface frame-relay 1.16
(config-fr 1.16)#dial-backup maximum-retry 4