Command Reference Guide ATM Sub-Interfa c e Config Command Set
61200510L1-35E Copyright © 2005 ADTRAN 771

oam retry <up-count> <down-count> <retry-frequency>

Use the oam retry command to configure parameters related to Operation, Administration, and

Maintenance (OAM) management for an ATM interface. Use the no form of this command to

disable OAM management parameters.

Syntax Description>
<up-count> S pecifies the number of consecutive end -to-end F5 OAM loopback cell resp onses
that must be received in order to change a PVC connection state to up. The range
is from 1 to 255.
<down-count> S pecifies the number of consecutive end-to-en d F5 OAM loopback cell responses
that are not received in orde r to change a PVC st ate to down. The range is from 1
to 255.
<retry-frequency> Specifies the frequency (in seconds) that end-to-end F5 OAM loopback cells are
transmitted when a change in the up/down state of a PVC is being verified. The
range is from 1 to 600.
Default Values
By default, the up-count is set to 3, the down-count is set to 5, and the retry frequency is 1.
Applicable Platforms
This command applies to the NetVanta 300, 1000R, 3000, and 4000 Series units.
Command History
Release 8.1 Command was introduced.
Usage Examples
The following example configures the OAM parameters with an up-count of 2, down-count of 2, and retry
frequency of 10 :
(config)#interface atm 1.1
(config-atm 1.1)#oam retry 2 2 10