Command Reference Guide Frame Relay Interface Config Command Set
61200510L1-35E Copyright © 2005 ADTRAN 850

frame-relay lmi-n392dce <threshold>

Use the frame-relay lmi-n392dce command to set the N392 error threshold for the DCE endpoint. Typical
applications should leave the default value for this setting. Use the no form of this command to return to
the default value.
Syntax Description
<threshold> Sets the threshold value (valid range: 1 to 10).
Default Values
By default, the error threshold for the DCE endpoint is set to three errors.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, 4000, and 5000 and Total Access 900 Series units.
Command History
Release 1.1 Command was introduced.
Functional Notes
If the error thre shol d is met, the signa ling state status is change d to dow n, indica tin g a se rvic e- affecting
condition. This condition is cleared once N393 consecutive error-free events are received. N392 defines
the number of errors required in a given event window, while N393 defines the number of polling events in
each window.
For example:
If N392 = and N393 = 4, then if three errors occur within any four events, the interface is determined
inactive.
Usage Examples
The following example sets the N392 threshold for 5 seconds:
(config)#interface frame-relay 1
(config-fr 1)#frame-relay lmi-n392dce 5